Compare commits

..
Author SHA1 Message Date
J. Nick Koston 3c2c850cb4 Merge remote-tracking branch 'origin/dev' into HEAD 2026-11-14 08:38:58 -06:00
J. Nick Koston 95e4837b99 Merge branch 'dev' into api-client-synced-trigger 2026-11-01 12:32:34 -10:00
J. Nick Koston 16f14317a7 [api] Check the initial states arrive before on_client_synced fires 2026-10-29 20:04:02 -10:00
J. Nick Koston 08387b0fb0 [api] Don't fire on_client_synced after answering a disconnect request 2026-10-29 19:37:09 -10:00
J. Nick Koston e18413c2b7 [api] Catch an early on_client_synced in the integration test
Log unconditionally at the start of the trigger, so firing before the
subscription is seen even when the api.connected condition is false.
2026-10-29 19:15:17 -10:00
J. Nick Koston 086bfba8b3 [api] Fire on_client_synced once the deferred batch has drained
A direct send from the automation could overtake initial states still
queued under backpressure, and the trigger fired even when the final
flush killed the connection. The pending state rides in active_iterator_,
so it costs no RAM and the loop keeps its single iterator check.
2026-10-29 19:14:18 -10:00
J. Nick Koston 92e8a64669 Merge branch 'automation-owning-args' into api-client-synced-trigger 2026-10-29 17:09:42 -10:00
J. Nick Koston 32bde52dba [core] Move owning_args tests next to the automation tests 2026-10-29 17:09:39 -10:00
J. Nick Koston 32240fd69f Merge branch 'automation-owning-args' into api-client-synced-trigger 2026-10-29 17:06:59 -10:00
J. Nick Koston 8aa327264a Merge remote-tracking branch 'origin/dev' into automation-owning-args 2026-10-29 17:06:57 -10:00
J. Nick Koston b9a5ccea65 Merge branch 'automation-owning-args' into api-client-synced-trigger 2026-10-29 16:38:25 -10:00
J. Nick Koston aee3476828 [core] Move owning_args from nextion into automation
Picks std::string over StringRef for automation arguments when the
automation contains a deferring action. Shared so other components can
pass StringRef to their triggers without a lifetime issue.
2026-10-29 16:37:14 -10:00
J. Nick Koston 602c751c2f [api] Add on_client_synced trigger and pass client info as StringRef
on_client_connected fires during the hello, before the client subscribes
to states, so state_subscription_only is never true inside it. The new
on_client_synced trigger fires once the initial states have been sent,
when the subscriptions sent with SubscribeStates are active.

All three client triggers now pass StringRef; automations that defer get
std::string copies, chosen at compile time by automation.owning_args().
2026-10-29 16:30:08 -10:00
29 changed files with 223 additions and 445 deletions

No files matched your search

+1 -1
View File
@@ -741,7 +741,7 @@ esphome/components/web_server_idf/* @dentra
esphome/components/weikai/* @DrCoolZic
esphome/components/weikai_i2c/* @DrCoolZic
esphome/components/weikai_spi/* @DrCoolZic
esphome/components/whirlpool/* @arpena @glmnet @Rodrigoah
esphome/components/whirlpool/* @arpena @glmnet
esphome/components/whynter/* @aeonsablaze
esphome/components/wiegand/* @ssieb
esphome/components/wireguard/* @droscy @lhoracek @thomas0bernard
+32 -15
View File
@@ -144,6 +144,7 @@ CONF_HOMEASSISTANT_SERVICES = "homeassistant_services"
CONF_HOMEASSISTANT_STATES = "homeassistant_states"
CONF_LISTEN_BACKLOG = "listen_backlog"
CONF_MAX_SEND_QUEUE = "max_send_queue"
CONF_ON_CLIENT_SYNCED = "on_client_synced"
CONF_OUTGOING_CONNECTION = "outgoing_connection"
CONF_STATE_SUBSCRIPTION_ONLY = "state_subscription_only"
@@ -453,6 +454,9 @@ CONFIG_SCHEMA = cv.All(
cv.Optional(CONF_ON_CLIENT_DISCONNECTED): automation.validate_automation(
single=True
),
cv.Optional(CONF_ON_CLIENT_SYNCED): automation.validate_automation(
single=True
),
# Connection limits to prevent memory exhaustion on resource-constrained devices
# Each connection uses ~500-1000 bytes of RAM plus system resources
# Platform defaults based on available RAM and network stack implementation:
@@ -706,21 +710,34 @@ async def to_code(config: ConfigType) -> None:
if (wizard_config := config.get(wizard.CONF_WIZARD)) is not None:
await wizard.to_code(wizard_config)
if CONF_ON_CLIENT_CONNECTED in config:
cg.add_define("USE_API_CLIENT_CONNECTED_TRIGGER")
await automation.build_automation(
var.get_client_connected_trigger(),
[(cg.std_string, "client_info"), (cg.std_string, "client_address")],
config[CONF_ON_CLIENT_CONNECTED],
)
if CONF_ON_CLIENT_DISCONNECTED in config:
cg.add_define("USE_API_CLIENT_DISCONNECTED_TRIGGER")
await automation.build_automation(
var.get_client_disconnected_trigger(),
[(cg.std_string, "client_info"), (cg.std_string, "client_address")],
config[CONF_ON_CLIENT_DISCONNECTED],
)
for conf_key, define, callback_method in (
(
CONF_ON_CLIENT_CONNECTED,
"USE_API_CLIENT_CONNECTED_TRIGGER",
"set_on_client_connected_callback",
),
(
CONF_ON_CLIENT_DISCONNECTED,
"USE_API_CLIENT_DISCONNECTED_TRIGGER",
"set_on_client_disconnected_callback",
),
(
CONF_ON_CLIENT_SYNCED,
"USE_API_CLIENT_SYNCED_TRIGGER",
"set_on_client_synced_callback",
),
):
if (automation_conf := config.get(conf_key)) is not None:
cg.add_define(define)
await automation.build_callback_automation(
var,
callback_method,
automation.owning_args(
[(cg.StringRef, "client_info"), (cg.StringRef, "client_address")],
automation_conf,
),
automation_conf,
)
if (encryption_config := config.get(CONF_ENCRYPTION, None)) is not None:
if key := encryption_config.get(CONF_KEY):
+20 -2
View File
@@ -251,6 +251,9 @@ void APIConnection::destroy_active_iterator_() {
this->iterator_storage_.initial_state.~InitialStateIterator();
break;
case ActiveIterator::NONE:
#ifdef USE_API_CLIENT_SYNCED_TRIGGER
case ActiveIterator::CLIENT_SYNCED_PENDING:
#endif
break;
}
this->active_iterator_ = ActiveIterator::NONE;
@@ -415,10 +418,25 @@ void APIConnection::process_active_iterator_() {
} else {
this->process_iterator_batch_(this->iterator_storage_.list_entities);
}
#ifdef USE_API_CLIENT_SYNCED_TRIGGER
} else if (this->active_iterator_ == ActiveIterator::CLIENT_SYNCED_PENDING) {
// Fired after the sync, not on SubscribeStates, so the subscriptions sent with it are active.
// Waits for the batch to drain so a direct send from the automation cannot overtake queued states.
// next_close: a DisconnectRequest this pass already answered; remove is only set next loop.
if (this->deferred_batch_.empty() && !this->flags_.remove && !this->flags_.next_close) {
this->active_iterator_ = ActiveIterator::NONE;
char peername[socket::SOCKADDR_STR_LEN];
this->parent_->get_client_synced_callback().call(StringRef(this->helper_->get_client_name()),
StringRef(this->helper_->get_peername_to(peername)));
}
#endif
} else { // INITIAL_STATE
if (this->iterator_storage_.initial_state.completed()) {
this->destroy_active_iterator_();
this->finalize_iterator_sync_();
#ifdef USE_API_CLIENT_SYNCED_TRIGGER
this->active_iterator_ = ActiveIterator::CLIENT_SYNCED_PENDING;
#endif
} else {
this->process_iterator_batch_(this->iterator_storage_.initial_state);
}
@@ -1936,8 +1954,8 @@ void APIConnection::complete_authentication_() {
#ifdef USE_API_CLIENT_CONNECTED_TRIGGER
{
char peername[socket::SOCKADDR_STR_LEN];
this->parent_->get_client_connected_trigger()->trigger(std::string(this->helper_->get_client_name()),
std::string(this->helper_->get_peername_to(peername)));
this->parent_->get_client_connected_callback().call(StringRef(this->helper_->get_client_name()),
StringRef(this->helper_->get_peername_to(peername)));
}
#endif
#ifdef USE_HOMEASSISTANT_TIME
+14 -2
View File
@@ -296,7 +296,11 @@ class APIConnection final : public APIServerConnectionBase {
this->flags_.state_subscription = true;
// Start initial state iterator only if no iterator is active
// If list_entities is running, we'll start initial_state when it completes
if (this->active_iterator_ == ActiveIterator::NONE) {
if (this->active_iterator_ == ActiveIterator::NONE
#ifdef USE_API_CLIENT_SYNCED_TRIGGER
|| this->active_iterator_ == ActiveIterator::CLIENT_SYNCED_PENDING
#endif
) {
this->begin_iterator_(ActiveIterator::INITIAL_STATE);
}
}
@@ -642,7 +646,15 @@ class APIConnection final : public APIServerConnectionBase {
// Group 2: Iterator union (saves ~16 bytes vs separate iterators)
// These iterators are never active simultaneously - list_entities runs to completion
// before initial_state begins, so we use a union with explicit construction/destruction.
enum class ActiveIterator : uint8_t { NONE, LIST_ENTITIES, INITIAL_STATE };
enum class ActiveIterator : uint8_t {
NONE,
LIST_ENTITIES,
INITIAL_STATE,
#ifdef USE_API_CLIENT_SYNCED_TRIGGER
// Initial states sent, on_client_synced not fired yet; uses no iterator storage
CLIENT_SYNCED_PENDING,
#endif
};
union IteratorUnion {
ListEntitiesIterator list_entities;
+6 -4
View File
@@ -257,9 +257,11 @@ void APIServer::remove_client_(uint8_t client_index) {
#ifdef USE_API_CLIENT_DISCONNECTED_TRIGGER
// Save client info before closing socket and removal for the trigger
char peername_buf[socket::SOCKADDR_STR_LEN];
std::string client_name(client->get_name());
std::string client_peername(client->get_peername_to(peername_buf));
char client_name[CLIENT_INFO_NAME_MAX_LEN];
strncpy(client_name, client->get_name(), sizeof(client_name) - 1);
client_name[sizeof(client_name) - 1] = '\0';
char peername[socket::SOCKADDR_STR_LEN];
client->get_peername_to(peername);
#endif
// Read before the swap-and-reset below destroys the connection
@@ -302,7 +304,7 @@ void APIServer::remove_client_(uint8_t client_index) {
#ifdef USE_API_CLIENT_DISCONNECTED_TRIGGER
// Fire trigger after client is removed so api.connected reflects the true state
this->client_disconnected_trigger_.trigger(client_name, client_peername);
this->client_disconnected_callback_.call(StringRef(client_name), StringRef(peername));
#endif
}
+23 -4
View File
@@ -277,11 +277,27 @@ class APIServer final : public Component
const std::vector<UserServiceDescriptor *> &get_user_services() const { return this->user_services_; }
#endif
#if defined(USE_API_CLIENT_CONNECTED_TRIGGER) || defined(USE_API_CLIENT_DISCONNECTED_TRIGGER) || \
defined(USE_API_CLIENT_SYNCED_TRIGGER)
/// Called with the client name and address, which are only valid during the call
using ClientCallback = Callback<void(StringRef, StringRef)>;
#endif
#ifdef USE_API_CLIENT_CONNECTED_TRIGGER
Trigger<std::string, std::string> *get_client_connected_trigger() { return &this->client_connected_trigger_; }
template<typename F> void set_on_client_connected_callback(F &&callback) {
this->client_connected_callback_ = ClientCallback::create(std::forward<F>(callback));
}
const ClientCallback &get_client_connected_callback() const { return this->client_connected_callback_; }
#endif
#ifdef USE_API_CLIENT_DISCONNECTED_TRIGGER
Trigger<std::string, std::string> *get_client_disconnected_trigger() { return &this->client_disconnected_trigger_; }
template<typename F> void set_on_client_disconnected_callback(F &&callback) {
this->client_disconnected_callback_ = ClientCallback::create(std::forward<F>(callback));
}
#endif
#ifdef USE_API_CLIENT_SYNCED_TRIGGER
template<typename F> void set_on_client_synced_callback(F &&callback) {
this->client_synced_callback_ = ClientCallback::create(std::forward<F>(callback));
}
const ClientCallback &get_client_synced_callback() const { return this->client_synced_callback_; }
#endif
protected:
@@ -343,10 +359,13 @@ class APIServer final : public Component
// Pointers and pointer-like types first (4 bytes each)
socket::ListenSocket *socket_{nullptr};
#ifdef USE_API_CLIENT_CONNECTED_TRIGGER
Trigger<std::string, std::string> client_connected_trigger_;
ClientCallback client_connected_callback_;
#endif
#ifdef USE_API_CLIENT_DISCONNECTED_TRIGGER
Trigger<std::string, std::string> client_disconnected_trigger_;
ClientCallback client_disconnected_callback_;
#endif
#ifdef USE_API_CLIENT_SYNCED_TRIGGER
ClientCallback client_synced_callback_;
#endif
// 4-byte aligned types
@@ -7,8 +7,6 @@
#include "esphome/core/automation.h"
#include "esphome/components/network/ip_address.h"
#include <atomic>
#ifdef USE_ETHERNET
#ifdef USE_ESP32
@@ -368,9 +366,6 @@ class EthernetComponent final : public Component {
#ifdef USE_ETHERNET_IP_STATE_LISTENERS
StaticVector<EthernetIPStateListener *, ESPHOME_ETHERNET_IP_STATE_LISTENERS> ip_state_listeners_;
#ifdef USE_ESP32
std::atomic<uint8_t> ip_state_pending_{0};
#endif
#endif
#ifdef USE_ETHERNET_CONNECT_TRIGGER
@@ -129,14 +129,6 @@ void EthernetComponent::log_error_and_mark_failed_(esp_err_t err, const char *me
void EthernetComponent::loop() {
const uint32_t now = App.get_loop_component_start_time();
#ifdef USE_ETHERNET_IP_STATE_LISTENERS
// The IP events arrive on the event task; the listeners publish states, so notify them here
if (this->ip_state_pending_.load(std::memory_order_acquire) != 0) {
this->ip_state_pending_.store(0, std::memory_order_relaxed);
this->notify_ip_state_listeners_();
}
#endif
switch (this->state_) {
case EthernetComponentState::STOPPED:
if (this->started_) {
@@ -778,8 +770,7 @@ void EthernetComponent::eth_event_handler(void *arg, esp_event_base_t event_base
event_name = "ETH connected";
// For static IP configurations, GOT_IP event may not fire, so notify IP listeners here
#if defined(USE_ETHERNET_IP_STATE_LISTENERS) && defined(USE_ETHERNET_MANUAL_IP)
global_eth_component->ip_state_pending_.store(1, std::memory_order_release);
global_eth_component->enable_loop_soon_any_context();
global_eth_component->notify_ip_state_listeners_();
#endif
#if USE_NETWORK_IPV6
// Start SLAAC on link-up, not after the DHCPv4 lease. This also restores the
@@ -807,9 +798,6 @@ void EthernetComponent::got_ip_event_handler(void *arg, esp_event_base_t event_b
const esp_netif_ip_info_t *ip_info = &event->ip_info;
ESP_LOGV(TAG, "[Ethernet event] ETH Got IP " IPSTR, IP2STR(&ip_info->ip));
global_eth_component->got_ipv4_address_ = true;
#ifdef USE_ETHERNET_IP_STATE_LISTENERS
global_eth_component->ip_state_pending_.store(1, std::memory_order_release);
#endif
#if USE_NETWORK_IPV6 && (USE_NETWORK_MIN_IPV6_ADDR_COUNT > 0)
global_eth_component->connected_ = global_eth_component->ipv6_count_ >= USE_NETWORK_MIN_IPV6_ADDR_COUNT;
global_eth_component->enable_loop_soon_any_context(); // Enable loop when connection state changes
@@ -817,6 +805,9 @@ void EthernetComponent::got_ip_event_handler(void *arg, esp_event_base_t event_b
global_eth_component->connected_ = true;
global_eth_component->enable_loop_soon_any_context(); // Enable loop when connection state changes
#endif /* USE_NETWORK_IPV6 */
#ifdef USE_ETHERNET_IP_STATE_LISTENERS
global_eth_component->notify_ip_state_listeners_();
#endif
}
#if USE_NETWORK_IPV6
@@ -828,9 +819,6 @@ void EthernetComponent::got_ip6_event_handler(void *arg, esp_event_base_t event_
// after a link flap fires another event for the same address.
struct esp_ip6_addr if_ip6s[CONFIG_LWIP_IPV6_NUM_ADDRESSES];
global_eth_component->ipv6_count_ = esp_netif_get_all_ip6(global_eth_component->eth_netif_, if_ip6s);
#ifdef USE_ETHERNET_IP_STATE_LISTENERS
global_eth_component->ip_state_pending_.store(1, std::memory_order_release);
#endif
#if (USE_NETWORK_MIN_IPV6_ADDR_COUNT > 0)
global_eth_component->connected_ =
global_eth_component->got_ipv4_address_ && (global_eth_component->ipv6_count_ >= USE_NETWORK_MIN_IPV6_ADDR_COUNT);
@@ -839,6 +827,9 @@ void EthernetComponent::got_ip6_event_handler(void *arg, esp_event_base_t event_
global_eth_component->connected_ = global_eth_component->got_ipv4_address_;
global_eth_component->enable_loop_soon_any_context(); // Enable loop when connection state changes
#endif
#ifdef USE_ETHERNET_IP_STATE_LISTENERS
global_eth_component->notify_ip_state_listeners_();
#endif
}
#endif /* USE_NETWORK_IPV6 */
+2 -6
View File
@@ -5,15 +5,13 @@ from esphome.const import CONF_MODEL
from esphome.types import ConfigType
AUTO_LOAD = ["climate_ir"]
CODEOWNERS = ["@glmnet", "@arpena", "@Rodrigoah"]
CODEOWNERS = ["@glmnet", "@arpena"]
whirlpool_ns = cg.esphome_ns.namespace("whirlpool")
WhirlpoolClimate = whirlpool_ns.class_("WhirlpoolClimate", climate_ir.ClimateIR)
Model = whirlpool_ns.enum("Model")
MODELS = Model.options(
"DG11J1-3A", "DG11J1-91", "HISENSE_ARG", "HITACHI_HCRA31NEWH", prefix="MODEL_"
)
MODELS = Model.options("DG11J1-3A", "DG11J1-91", "HISENSE_ARG", prefix="MODEL_")
CONFIG_SCHEMA = climate_ir.climate_ir_with_receiver_schema(WhirlpoolClimate).extend(
{
@@ -28,5 +26,3 @@ async def to_code(config: ConfigType) -> None:
# cv.enum keeps the YAML key as a str subclass; the MockObj value cannot be compared
if config[CONF_MODEL] == "HISENSE_ARG":
cg.add_define("USE_WHIRLPOOL_HISENSE_ARG")
elif config[CONF_MODEL] == "HITACHI_HCRA31NEWH":
cg.add_define("USE_WHIRLPOOL_HITACHI_HCRA31NEWH")
+15 -61
View File
@@ -2,8 +2,6 @@
#include "esphome/core/helpers.h"
#include "esphome/core/log.h"
#include <algorithm>
namespace esphome::whirlpool {
ESPHOME_LOG_TAG(TAG, "whirlpool.climate");
@@ -46,17 +44,6 @@ static constexpr uint8_t HISENSE_ARG_POWER_TOGGLE = 0x01; // byte 15
static constexpr uint8_t HISENSE_ARG_SETTINGS_ONLY = 0x02; // byte 15
static constexpr uint8_t HISENSE_ARG_FIXED_TEMP_STEP = 7; // auto and fan-only send 23 C
// Hitachi HCRA31NEWH model: power is a state in every frame
static constexpr uint8_t HITACHI_BYTE10 = 0x20; // byte 10
static constexpr uint8_t HITACHI_COOL = 0x02; // byte 15
static constexpr uint8_t HITACHI_OFF = 0x01; // byte 15
static constexpr uint8_t HITACHI_BYTE18_ON = 0x38; // byte 18
static constexpr uint8_t HITACHI_BYTE18_OFF = 0x28; // byte 18
static constexpr uint8_t HITACHI_BYTE19 = 0x08; // byte 19
// Header, 21 bytes of 8 bits, two dividers and the footer mark
static constexpr uint32_t WHIRLPOOL_FRAME_TIMINGS = 2 + WHIRLPOOL_STATE_LENGTH * 16 + 2 * 2 + 1;
WhirlpoolClimate::WhirlpoolClimate()
: climate_ir::ClimateIR(
WHIRLPOOL_DG11J1_3A_TEMP_MIN, WHIRLPOOL_DG11J1_3A_TEMP_MAX, 1.0f, true, true,
@@ -68,19 +55,19 @@ void WhirlpoolClimate::transmit_state() {
this->last_transmit_time_ = millis(); // setting the time of the last transmission.
uint8_t remote_state[WHIRLPOOL_STATE_LENGTH];
memset(remote_state, 0, sizeof(remote_state));
put_be16(remote_state, this->remote_id_());
remote_state[0] = 0x83;
remote_state[1] = 0x06;
remote_state[6] = 0x80;
remote_state[18] = 0x08;
remote_state[18] = 0x08; // the same on every supported model
const bool powered_on = this->mode != climate::CLIMATE_MODE_OFF;
// Hitachi sends power as a state instead of a toggle
const bool power_toggle = !this->is_hitachi_hcra31newh_() && powered_on != this->powered_on_assumed;
auto powered_on = this->mode != climate::CLIMATE_MODE_OFF;
const bool power_toggle = powered_on != this->powered_on_assumed;
if (power_toggle) {
// Set power toggle command
remote_state[2] = 4;
remote_state[15] = 1;
this->powered_on_assumed = powered_on;
}
this->powered_on_assumed = powered_on;
switch (this->mode) {
case climate::CLIMATE_MODE_HEAT_COOL:
// set fan auto
@@ -106,10 +93,6 @@ void WhirlpoolClimate::transmit_state() {
remote_state[15] = 6;
break;
case climate::CLIMATE_MODE_OFF:
// These remotes keep the cool code in the power-off frame
if (this->is_hisense_arg_() || this->is_hitachi_hcra31newh_())
remote_state[3] = WHIRLPOOL_COOL;
break;
default:
break;
}
@@ -119,7 +102,6 @@ void WhirlpoolClimate::transmit_state() {
// Temperature
auto temp = (uint8_t) roundf(clamp(this->target_temperature, this->temperature_min_(), this->temperature_max_()));
const auto temp_step = (uint8_t) (temp - this->temperature_min_());
this->target_temperature = temp; // publish what the unit was sent
if (hisense_arg && this->fixed_temp_mode_()) {
remote_state[3] |= HISENSE_ARG_FIXED_TEMP_STEP << 4;
} else {
@@ -149,6 +131,7 @@ void WhirlpoolClimate::transmit_state() {
remote_state[2] |= WHIRLPOOL_SWING_MASK;
remote_state[8] = WHIRLPOOL_SWING_BYTE8;
}
this->encode_hisense_arg_(remote_state, power_toggle, temp_step);
} else if (this->send_swing_cmd_) {
if (this->swing_mode == climate::CLIMATE_SWING_VERTICAL || this->swing_mode == climate::CLIMATE_SWING_OFF) {
remote_state[2] |= WHIRLPOOL_SWING_MASK;
@@ -156,11 +139,6 @@ void WhirlpoolClimate::transmit_state() {
}
}
if (hisense_arg)
this->encode_hisense_arg_(remote_state, power_toggle, temp_step);
if (this->is_hitachi_hcra31newh_())
this->encode_hitachi_hcra31newh_(remote_state);
// Checksum
remote_state[13] = xor_bytes(&remote_state[2], 11, remote_state[13]);
remote_state[20] = xor_bytes(&remote_state[14], 6, remote_state[20]);
@@ -170,7 +148,6 @@ void WhirlpoolClimate::transmit_state() {
// Send code
auto transmit = this->transmitter_->transmit();
auto *data = transmit.get_data();
data->reserve(WHIRLPOOL_FRAME_TIMINGS);
data->set_carrier_frequency(38000);
@@ -203,6 +180,10 @@ void WhirlpoolClimate::encode_hisense_arg_(uint8_t *remote_state, bool power_tog
remote_state[15] = power_toggle ? HISENSE_ARG_POWER_TOGGLE : HISENSE_ARG_SETTINGS_ONLY;
switch (this->mode) {
case climate::CLIMATE_MODE_OFF:
// The remote keeps the cool code in the power-off frame
remote_state[3] = (remote_state[3] & 0xF0) | WHIRLPOOL_COOL;
break;
case climate::CLIMATE_MODE_DRY:
// The unit runs these fan speeds itself; the user's choice is kept for the next mode change
remote_state[2] &= ~WHIRLPOOL_FAN_MASK;
@@ -231,27 +212,6 @@ void WhirlpoolClimate::encode_hisense_arg_(uint8_t *remote_state, bool power_tog
#endif
}
void WhirlpoolClimate::encode_hitachi_hcra31newh_(uint8_t *remote_state) const {
#ifdef USE_WHIRLPOOL_HITACHI_HCRA31NEWH
remote_state[10] = HITACHI_BYTE10;
remote_state[18] = HITACHI_BYTE18_ON;
remote_state[19] = HITACHI_BYTE19;
// The unit takes the whole state from every frame: only the off frame carries the power bit
switch (this->mode) {
case climate::CLIMATE_MODE_COOL:
remote_state[15] = HITACHI_COOL;
break;
case climate::CLIMATE_MODE_OFF:
remote_state[2] |= WHIRLPOOL_POWER;
remote_state[15] = HITACHI_OFF;
remote_state[18] = HITACHI_BYTE18_OFF;
break;
default:
break;
}
#endif
}
bool WhirlpoolClimate::on_receive(remote_base::RemoteReceiveData data) {
// Check if the esp isn't currently transmitting.
if (millis() - this->last_transmit_time_ < 500) {
@@ -274,8 +234,7 @@ bool WhirlpoolClimate::on_receive(remote_base::RemoteReceiveData data) {
if (!data.expect_item(WHIRLPOOL_BIT_MARK, WHIRLPOOL_GAP))
return false;
}
// The Hitachi remote always sends all 21 bytes; byte 18 holds its power state
if (i == WHIRLPOOL_SECOND_DIVIDER && !data.is_valid() && !this->is_hitachi_hcra31newh_()) {
if (i == WHIRLPOOL_SECOND_DIVIDER && !data.is_valid()) {
// Remote control only sent 14 bytes, nothing more to read, not even the footer
ESP_LOGV(TAG, "Remote control only sent %d bytes", i);
skip_footer = true;
@@ -302,18 +261,13 @@ bool WhirlpoolClimate::on_receive(remote_base::RemoteReceiveData data) {
ESP_LOGV_HEX(TAG, remote_state, WHIRLPOOL_STATE_LENGTH, WHIRLPOOL_STATE_LENGTH, "Received: %s");
// verify header remote code
if (encode_uint16(remote_state[0], remote_state[1]) != this->remote_id_())
if (remote_state[0] != 0x83 || remote_state[1] != 0x06)
return false;
// powr on/off button
ESP_LOGV(TAG, "Power: %02X", (remote_state[2] & WHIRLPOOL_POWER));
if (this->is_hitachi_hcra31newh_()) {
// Power is a state: byte 18 says whether the unit is off
this->powered_on_assumed = remote_state[18] != HITACHI_BYTE18_OFF;
if (!this->powered_on_assumed)
this->mode = climate::CLIMATE_MODE_OFF;
} else if ((remote_state[2] & WHIRLPOOL_POWER) == WHIRLPOOL_POWER) {
if ((remote_state[2] & WHIRLPOOL_POWER) == WHIRLPOOL_POWER) {
auto powered_on = this->mode != climate::CLIMATE_MODE_OFF;
if (powered_on) {
@@ -355,7 +309,7 @@ bool WhirlpoolClimate::on_receive(remote_base::RemoteReceiveData data) {
int temp = remote_state[3] & 0xF0;
ESP_LOGVV(TAG, "Temperature Raw: %02X", temp);
temp = (uint8_t) temp >> 4;
temp = std::min(temp + static_cast<int>(this->temperature_min_()), static_cast<int>(this->temperature_max_()));
temp += static_cast<int>(this->temperature_min_());
ESP_LOGVV(TAG, "Temperature Climate: %u", temp);
this->target_temperature = temp;
}
+4 -19
View File
@@ -6,10 +6,9 @@ namespace esphome::whirlpool {
/// Simple enum to represent models.
enum Model {
MODEL_DG11J1_3A = 0, /// Temperature range is from 18 to 32
MODEL_DG11J1_91 = 1, /// Temperature range is from 16 to 30
MODEL_HISENSE_ARG = 2, /// Hisense/BGH (Argentina), 16 to 30
MODEL_HITACHI_HCRA31NEWH = 3, /// Hitachi with the HCRA31NEWH remote, 16 to 30
MODEL_DG11J1_3A = 0, /// Temperature range is from 18 to 32
MODEL_DG11J1_91 = 1, /// Temperature range is from 16 to 30
MODEL_HISENSE_ARG = 2, /// Hisense/BGH (Argentina), 16 to 30
};
// Temperature
@@ -30,9 +29,7 @@ class WhirlpoolClimate final : public climate_ir::ClimateIR {
/// Override control to change settings of the climate device.
void control(const climate::ClimateCall &call) override {
// The toggle remotes flip swing on every press, so only send one when the mode really changes
auto swing = call.get_swing_mode();
this->send_swing_cmd_ = swing.has_value() && *swing != this->swing_mode;
send_swing_cmd_ = call.get_swing_mode().has_value();
climate_ir::ClimateIR::control(call);
}
@@ -58,22 +55,10 @@ class WhirlpoolClimate final : public climate_ir::ClimateIR {
return false;
#endif
}
/// False when the model is compiled out, so the compiler drops the Hitachi branches.
bool is_hitachi_hcra31newh_() const {
#ifdef USE_WHIRLPOOL_HITACHI_HCRA31NEWH
return this->model_ == MODEL_HITACHI_HCRA31NEWH;
#else
return false;
#endif
}
/// The remote ID sent in bytes 0 and 1.
uint16_t remote_id_() const { return this->is_hitachi_hcra31newh_() ? 0xA959 : 0x8306; }
/// Modes in which the Hisense ARG model sends a fixed temperature.
bool fixed_temp_mode_() const;
/// Add the Hisense ARG bytes on top of the common whirlpool frame.
void encode_hisense_arg_(uint8_t *remote_state, bool power_toggle, uint8_t temp_step) const;
/// Add the Hitachi HCRA31NEWH bytes on top of the common whirlpool frame.
void encode_hitachi_hcra31newh_(uint8_t *remote_state) const;
/// Set the time of the last transmission.
uint32_t last_transmit_time_{};
+1 -1
View File
@@ -563,7 +563,7 @@ class WiFiComponent final : public Component {
// (In most use cases you won't need these)
/// Setup WiFi interface.
void setup() override;
#if defined(USE_ESP32) || defined(USE_LN882X) || defined(USE_BK72XX)
#if defined(USE_LN882X) || defined(USE_BK72XX)
void on_powerdown() override;
#endif
void start();
@@ -1635,21 +1635,6 @@ bool WiFiComponent::wifi_dpp_start_listen_() {
void WiFiComponent::wifi_dpp_stop_listen_() { esp_supp_dpp_stop_listen(); }
#endif
void WiFiComponent::on_powerdown() {
// Leave the AP before esp_restart() or deep sleep stops Wi-Fi. esp_wifi_stop() while associated
// makes the ESP32 retransmit its Disassociation up to the retry limit although the AP ACKs it
// (32 copies with protected management frames), which some APs handle badly.
// Upstream bug: https://github.com/espressif/esp-idf/issues/19443 - remove this once it is fixed
// in the ESP-IDF versions we support.
// Ask the driver: s_sta_connected lags until the main loop has handled the connect event.
wifi_ap_record_t ap_info;
if (esp_wifi_sta_get_ap_info(&ap_info) != ESP_OK)
return;
ESP_LOGD(TAG, "Disconnecting before powerdown");
esp_wifi_disconnect();
delay(100); // NOLINT: once per reboot or deep sleep, lets the disassociation go out
}
bool WiFiComponent::wifi_disconnect_() { return esp_wifi_disconnect(); }
bssid_t WiFiComponent::wifi_bssid() {
-2
View File
@@ -294,8 +294,6 @@ void Application::reboot() {
for (auto &component : std::ranges::reverse_view(this->components_)) {
component->on_shutdown();
}
// No teardown on a forced reboot, but still power hardware down (Wi-Fi leaves the AP)
this->run_powerdown_hooks();
arch_restart();
}
void Application::safe_reboot() {
+2 -4
View File
@@ -185,12 +185,10 @@ class Component {
*/
virtual bool teardown() { return true; }
/** Called last before a reboot or deep sleep to power down hardware.
/** Called after teardown is complete to power down hardware.
*
* On a safe shutdown this is called after all components have finished their teardown process,
* This is called after all components have finished their teardown process,
* making it safe to power down hardware like ethernet PHY.
* On a forced reboot (Application::reboot()) it is called right after on_shutdown() with no
* teardown, so implementations must not assume teardown() has run.
*/
virtual void on_powerdown() {}
+1 -1
View File
@@ -387,7 +387,6 @@
#define USE_WATER_HEATER
#define USE_WATER_HEATER_VISUAL_OVERRIDES
#define USE_WHIRLPOOL_HISENSE_ARG
#define USE_WHIRLPOOL_HITACHI_HCRA31NEWH
#define USE_ZWAVE_PROXY
// Feature flags which do not work for zephyr
@@ -402,6 +401,7 @@
#define USE_API
#define USE_API_CLIENT_CONNECTED_TRIGGER
#define USE_API_CLIENT_DISCONNECTED_TRIGGER
#define USE_API_CLIENT_SYNCED_TRIGGER
#define USE_API_HOMEASSISTANT_ACTION_RESPONSES
#define USE_API_HOMEASSISTANT_ACTION_RESPONSES_JSON
#define USE_API_HOMEASSISTANT_SERVICES
+10
View File
@@ -98,6 +98,16 @@ esphome:
api:
port: 8000
reboot_timeout: 0min
on_client_connected:
# Deferring actions get owned copies of the arguments
- delay: 1s
- logger.log:
format: "Client %s connected from %s"
args: [client_info.c_str(), client_address.c_str()]
on_client_synced:
- logger.log:
format: "Client %s synced from %s"
args: [client_info.c_str(), client_address.c_str()]
actions:
- action: hello_world
description: Log a greeting
@@ -2,7 +2,3 @@ packages:
i2c: !include ../../test_build_components/common/i2c/esp32-idf.yaml
<<: !include common.yaml
# IPv6 with an IP sensor: compiles the IPv6 event handler's listener notification
network:
enable_ipv6: true
+1 -2
View File
@@ -10,8 +10,7 @@ def override_manifest(manifest: ComponentManifestOverride) -> None:
manifest.auto_load = ["climate_ir", "climate"]
async def to_code_testing(config: ConfigType) -> None:
# Compiles in the Hisense ARG and Hitachi models, which climate.py adds only when configured
# Compiles in the Hisense ARG model, which climate.py adds only when it is configured
cg.add_define("USE_WHIRLPOOL_HISENSE_ARG")
cg.add_define("USE_WHIRLPOOL_HITACHI_HCRA31NEWH")
manifest.to_code = to_code_testing
-5
View File
@@ -8,8 +8,3 @@ climate:
model: HISENSE_ARG
transmitter_id: xmitr
receiver_id: rcvr
- platform: whirlpool
name: Whirlpool Hitachi HCRA31NEWH Climate
model: HITACHI_HCRA31NEWH
transmitter_id: xmitr
receiver_id: rcvr
@@ -252,9 +252,6 @@ TEST(WhirlpoolHisenseArg, SwingIsSentOnEveryTransmit) {
TEST(WhirlpoolDG11J13A, SwingIsSentOnlyWhenItChanges) {
Fixture f(MODEL_DG11J1_3A);
f.command(climate::CLIMATE_MODE_COOL, 24, climate::CLIMATE_FAN_LOW, climate::CLIMATE_SWING_OFF);
EXPECT_EQ(f.last_frame()[2] & 0x80, 0) << "swing is already off";
f.command(climate::CLIMATE_MODE_COOL, 24, climate::CLIMATE_FAN_LOW, climate::CLIMATE_SWING_VERTICAL);
Frame frame = f.last_frame();
EXPECT_EQ(frame[2] & 0x80, 0x80);
@@ -264,9 +261,6 @@ TEST(WhirlpoolDG11J13A, SwingIsSentOnlyWhenItChanges) {
frame = f.last_frame();
EXPECT_EQ(frame[2] & 0x80, 0);
EXPECT_EQ(frame[8], 0x00);
f.command(climate::CLIMATE_MODE_COOL, 25, climate::CLIMATE_FAN_LOW, climate::CLIMATE_SWING_VERTICAL);
EXPECT_EQ(f.last_frame()[2] & 0x80, 0) << "swing is already vertical";
}
// Cool 24 C (step 8), fan low, powered on assumed
@@ -391,90 +385,4 @@ TEST(WhirlpoolHisenseArg, EveryTransmitHasValidChecksums) {
}
}
// Cool 24 C (step 8), fan low, unit on
static Frame hitachi_cool_frame() {
return with_checksums({0xA9, 0x59, 0x03, 0x82, 0x00, 0x00, 0x80, 0x00, 0x00, 0x00, 0x20,
0x00, 0x00, 0x00, 0x00, 0x02, 0x00, 0x00, 0x38, 0x08, 0x00});
}
// The off frame: power bit, cool code, byte 15 0x01 and byte 18 0x28
static Frame hitachi_off_frame() {
return with_checksums({0xA9, 0x59, 0x07, 0x82, 0x00, 0x00, 0x80, 0x00, 0x00, 0x00, 0x20,
0x00, 0x00, 0x00, 0x00, 0x01, 0x00, 0x00, 0x28, 0x08, 0x00});
}
TEST(WhirlpoolHitachiHCRA31NEWH, CoolAndOffMatchKnownFrames) {
Fixture f(MODEL_HITACHI_HCRA31NEWH);
f.command(climate::CLIMATE_MODE_COOL, 24, climate::CLIMATE_FAN_LOW);
// Turning on sends the full state with no power bit
expect_frame(f.last_frame(), hitachi_cool_frame());
f.command(climate::CLIMATE_MODE_OFF, 24, climate::CLIMATE_FAN_LOW);
expect_frame(f.last_frame(), hitachi_off_frame());
// A second off command still sends the power bit
f.command(climate::CLIMATE_MODE_OFF, 24, climate::CLIMATE_FAN_LOW);
EXPECT_EQ(f.last_frame()[2] & 0x04, 0x04);
f.command(climate::CLIMATE_MODE_HEAT, 24, climate::CLIMATE_FAN_LOW);
const Frame frame = f.last_frame();
EXPECT_EQ(frame[2] & 0x04, 0);
EXPECT_EQ(frame[3], 0x80);
EXPECT_EQ(frame[15], 0x06);
EXPECT_EQ(frame[18], 0x38);
}
TEST(WhirlpoolHitachiHCRA31NEWH, ReceivePowerIsAState) {
Fixture f(MODEL_HITACHI_HCRA31NEWH);
ASSERT_EQ(f.climate.mode, climate::CLIMATE_MODE_OFF);
// An on frame restores the mode even though it has no power bit
EXPECT_TRUE(receive(f.climate, hitachi_cool_frame()));
EXPECT_EQ(f.climate.mode, climate::CLIMATE_MODE_COOL);
EXPECT_FLOAT_EQ(f.climate.target_temperature, 24);
EXPECT_EQ(f.climate.fan_mode, climate::CLIMATE_FAN_LOW);
// The same frame again keeps it on
EXPECT_TRUE(receive(f.climate, hitachi_cool_frame()));
EXPECT_EQ(f.climate.mode, climate::CLIMATE_MODE_COOL);
EXPECT_TRUE(receive(f.climate, hitachi_off_frame()));
EXPECT_EQ(f.climate.mode, climate::CLIMATE_MODE_OFF);
// A repeated off frame does not toggle
EXPECT_TRUE(receive(f.climate, hitachi_off_frame()));
EXPECT_EQ(f.climate.mode, climate::CLIMATE_MODE_OFF);
}
TEST(WhirlpoolHitachiHCRA31NEWH, ReceiveChecksRemoteId) {
Fixture hitachi(MODEL_HITACHI_HCRA31NEWH);
EXPECT_FALSE(receive(hitachi.climate, hisense_cool_frame()));
Fixture whirlpool(MODEL_DG11J1_91);
EXPECT_FALSE(receive(whirlpool.climate, hitachi_cool_frame()));
}
TEST(WhirlpoolHitachiHCRA31NEWH, ReceivedTemperatureIsClamped) {
Fixture f(MODEL_HITACHI_HCRA31NEWH);
Frame frame = hitachi_cool_frame();
frame[3] = 0xF2; // step 15 would be 31 C
EXPECT_TRUE(receive(f.climate, with_checksums(frame)));
EXPECT_FLOAT_EQ(f.climate.target_temperature, 30);
}
TEST(WhirlpoolDG11J13A, TargetIsClampedAndRoundedToWhatWasSent) {
Fixture f(MODEL_DG11J1_3A);
f.command(climate::CLIMATE_MODE_COOL, 35, climate::CLIMATE_FAN_LOW);
EXPECT_FLOAT_EQ(f.climate.target_temperature, 32);
f.command(climate::CLIMATE_MODE_COOL, 24.4f, climate::CLIMATE_FAN_LOW);
EXPECT_FLOAT_EQ(f.climate.target_temperature, 24);
}
TEST(WhirlpoolHitachiHCRA31NEWH, ReceiveRejectsShortFrame) {
Fixture f(MODEL_HITACHI_HCRA31NEWH);
remote_base::RawTimings raw = waveform(hitachi_cool_frame());
// Cut after the second divider: 14 bytes, no footer
raw.resize(2 + 14 * 16 + 2 * 2);
remote_base::RemoteReceiveData data(raw, 25, remote_base::TOLERANCE_MODE_PERCENTAGE);
EXPECT_FALSE(static_cast<remote_base::RemoteReceiverListener &>(f.climate).on_receive(data));
EXPECT_EQ(f.climate.mode, climate::CLIMATE_MODE_OFF);
}
} // namespace esphome::whirlpool::testing
@@ -0,0 +1,28 @@
esphome:
name: api-client-synced
host:
api:
on_client_synced:
- logger.log: "Synced trigger entered"
- if:
condition:
api.connected:
state_subscription_only: true
then:
- logger.log: "Synced trigger fired"
# Home Assistant subscribes to actions in the same packet as states
- homeassistant.event:
event: esphome.client_synced
switch:
# A known state at boot, so the test can check it is sent before the trigger
- platform: template
id: ready_switch
name: "Ready switch"
optimistic: true
restore_mode: ALWAYS_ON
logger:
level: DEBUG
@@ -1,23 +0,0 @@
import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.const import CONF_ID, CONF_NAME
from esphome.types import ConfigType
CODEOWNERS = ["@esphome/tests"]
MULTI_CONF = True
reboot_hook_recorder_ns = cg.esphome_ns.namespace("reboot_hook_recorder")
RebootHookRecorder = reboot_hook_recorder_ns.class_("RebootHookRecorder", cg.Component)
CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(): cv.declare_id(RebootHookRecorder),
cv.Required(CONF_NAME): cv.string,
}
).extend(cv.COMPONENT_SCHEMA)
async def to_code(config: ConfigType) -> None:
var = cg.new_Pvariable(config[CONF_ID])
await cg.register_component(var, config)
cg.add(var.set_name(config[CONF_NAME]))
@@ -1,10 +0,0 @@
#include "reboot_hook_recorder.h"
#include "esphome/core/log.h"
namespace esphome::reboot_hook_recorder {
ESPHOME_LOG_TAG(TAG, "reboot_hook_recorder");
void RebootHookRecorder::record_(const char *hook) { ESP_LOGI(TAG, "HOOK %s %s", this->name_, hook); }
} // namespace esphome::reboot_hook_recorder
@@ -1,33 +0,0 @@
#pragma once
#include "esphome/core/component.h"
namespace esphome::reboot_hook_recorder {
/// Logs every shutdown lifecycle hook it receives, so a test can check their order.
class RebootHookRecorder : public Component {
public:
void set_name(const char *name) { this->name_ = name; }
void on_safe_shutdown() override { this->record_("on_safe_shutdown"); }
void on_shutdown() override { this->record_("on_shutdown"); }
// Needs a second call to finish, like a component waiting for a connection to close
bool teardown() override {
if (++this->teardown_calls_ < 2) {
this->record_("teardown_pending");
return false;
}
if (this->teardown_calls_ == 2)
this->record_("teardown_done");
return true;
}
void on_powerdown() override { this->record_("on_powerdown"); }
protected:
void record_(const char *hook);
const char *name_{""};
uint8_t teardown_calls_{0};
};
} // namespace esphome::reboot_hook_recorder
@@ -1,19 +0,0 @@
esphome:
name: reboot-hooks-forced
host:
logger:
level: DEBUG
api:
# Reboot once the test has connected, so that it sees every hook
on_client_connected:
- delay: 100ms
- lambda: App.reboot();
external_components:
- source:
type: local
path: EXTERNAL_COMPONENT_PATH
reboot_hook_recorder:
- name: first
- name: second
@@ -1,19 +0,0 @@
esphome:
name: reboot-hooks-safe
host:
logger:
level: DEBUG
api:
# Reboot once the test has connected, so that it sees every hook
on_client_connected:
- delay: 100ms
- lambda: App.safe_reboot();
external_components:
- source:
type: local
path: EXTERNAL_COMPONENT_PATH
reboot_hook_recorder:
- name: first
- name: second
@@ -0,0 +1,56 @@
"""Integration test for the api on_client_synced trigger."""
from __future__ import annotations
import asyncio
from aioesphomeapi import EntityState, HomeassistantServiceCall, SwitchState
import pytest
from .log_utils import LineWaiter
from .types import APIClientConnectedFactory, RunCompiledFunction
@pytest.mark.asyncio
async def test_api_client_synced(
yaml_config: str,
run_compiled: RunCompiledFunction,
api_client_connected: APIClientConnectedFactory,
) -> None:
"""The trigger fires after the initial states, with the action subscription active."""
waiter = LineWaiter()
calls: asyncio.Queue[HomeassistantServiceCall] = asyncio.Queue()
# Everything the client receives, in order
received: list[EntityState | HomeassistantServiceCall] = []
def on_service_call(call: HomeassistantServiceCall) -> None:
received.append(call)
calls.put_nowait(call)
async with (
run_compiled(yaml_config, line_callback=waiter.callback),
api_client_connected() as client,
):
await client.device_info()
assert waiter.count("Synced trigger entered") == 0
client.subscribe_home_assistant_states_and_services(
on_state=received.append,
on_service_call=on_service_call,
on_state_sub=lambda *_: None,
)
await waiter.wait_for_each(
"Synced trigger entered", "Synced trigger fired", timeout=5.0
)
call = await asyncio.wait_for(calls.get(), timeout=5.0)
assert call.service == "esphome.client_synced"
assert call.is_event
# The initial switch state arrives before the trigger's event
synced_at = received.index(call)
switch_states = [
i
for i, item in enumerate(received[:synced_at])
if isinstance(item, SwitchState)
]
assert switch_states, received
assert received[switch_states[0]].state is True
@@ -1,80 +0,0 @@
"""Test the order of the shutdown lifecycle hooks on a forced and on a safe reboot."""
import re
import pytest
from .log_utils import LineWaiter
from .types import APIClientConnectedFactory, RunCompiledFunction
from .wait_utils import wait_or_fail
HOOK_PATTERN = re.compile(r"HOOK (\w+) (\w+)")
# Hooks run in reverse component order, so "first" gets each hook last.
LAST_HOOK = "HOOK first on_powerdown"
async def _record_reboot_hooks(
yaml_config: str,
run_compiled: RunCompiledFunction,
api_client_connected: APIClientConnectedFactory,
) -> list[tuple[str, str]]:
"""Connect, which makes the device reboot, and return its (component, hook) calls in order."""
waiter = LineWaiter()
hooks: list[tuple[str, str]] = []
def on_line(line: str) -> None:
if match := HOOK_PATTERN.search(line):
hooks.append((match[1], match[2]))
waiter.callback(line)
async with (
run_compiled(yaml_config, line_callback=on_line),
api_client_connected(),
):
await wait_or_fail(
waiter.wait_for(LAST_HOOK),
5.0,
"Device did not run the powerdown hooks",
hooks=hooks,
)
return hooks
@pytest.mark.asyncio
async def test_reboot_hook_order_forced(
yaml_config: str,
run_compiled: RunCompiledFunction,
api_client_connected: APIClientConnectedFactory,
) -> None:
"""A forced reboot runs on_shutdown then on_powerdown, with no safe shutdown or teardown."""
hooks = await _record_reboot_hooks(yaml_config, run_compiled, api_client_connected)
assert hooks == [
("second", "on_shutdown"),
("first", "on_shutdown"),
("second", "on_powerdown"),
("first", "on_powerdown"),
]
@pytest.mark.asyncio
async def test_reboot_hook_order_safe(
yaml_config: str,
run_compiled: RunCompiledFunction,
api_client_connected: APIClientConnectedFactory,
) -> None:
"""A safe reboot powers down only after every component has finished its teardown."""
hooks = await _record_reboot_hooks(yaml_config, run_compiled, api_client_connected)
assert hooks == [
("second", "on_safe_shutdown"),
("first", "on_safe_shutdown"),
("second", "on_shutdown"),
("first", "on_shutdown"),
("second", "teardown_pending"),
("first", "teardown_pending"),
("second", "teardown_done"),
("first", "teardown_done"),
("second", "on_powerdown"),
("first", "on_powerdown"),
]