Files
esphome/storage-heater.yaml
T

21 lines
417 B
YAML

substitutions:
name: "storage-heater"
friendly_name: "Storage heater"
esphome:
area: "Storage"
packages:
device_base: !include templates/mystrom.yaml
sensor:
- platform: duty_time
id: row_heating_time
name: Row heating time
lambda: "return id(mystrom_relay).state;"
on_value_range:
above: 18000 # 5h
then:
- switch.turn_off: mystrom_relay
- sensor.duty_time.reset: row_heating_time