Update watermeter limits
This commit is contained in:
+9
-9
@@ -13,17 +13,17 @@ packages:
|
||||
|
||||
sensor:
|
||||
- platform: pulse_meter
|
||||
# Our meter (USLF20) is rated Q3=4.0 (m3/h).
|
||||
# The official one is rated 5.0 (assuming also Q3).
|
||||
# There's no Q4 value available.
|
||||
# Our meter (USLC/20) is rated Qmax=5.0 (m3/h).
|
||||
# The official one is rated 5.0.
|
||||
#
|
||||
# 3600 / 5000 = 0.72 seconds per liter. That's the shortest
|
||||
# pulse length at a normal flow rate for the meter. Assuming
|
||||
# 5x worst case, take 100ms as a reasonable margin.
|
||||
internal_filter: 100ms
|
||||
# Assuming Q1=70 (l/h), a flow with 52 second between pulses
|
||||
# is beyond the measuring capabilities.
|
||||
timeout: 1min
|
||||
# pulse length at a maximum flow rate for the meter.
|
||||
internal_filter: 720ms
|
||||
# Assuming Qmin=50 (l/h), a flow with >72 seconds between pulses
|
||||
# is beyond the measuring capabilities (0.83 L/min which is just
|
||||
# below irrigation consumption).
|
||||
timeout: 72s
|
||||
|
||||
pin:
|
||||
number: D2
|
||||
inverted: true
|
||||
|
||||
Reference in New Issue