Remove recirculation-pump (switched to Shelly)

This commit is contained in:
2025-07-21 21:58:24 +02:00
parent e4b8eb2a7c
commit 1f71adbe33
-33
View File
@@ -1,33 +0,0 @@
substitutions:
name: "recirculation-pump"
friendly_name: "Recirculation pump"
esphome:
area: "Workshop"
packages:
device_base: !include templates/mystrom.yaml
time: !include templates/time.yaml
time:
- platform: sntp
id: sntp_time
servers: !secret sntp_servers
on_time:
# Heating schedule is 5AM to 8PM. Judging by the burner state, it means that
# by 5AM the water is expected to be hot (60C) and at 8PM it's expected to be
# still hot as well (within the normal range of 56-60C).
#
# There's also an automation in HA to turn the pump on when boiler is heating.
#
# Otherwise, pump every 30 minutes for 3 minutes long.
- hours: "5-20"
minutes: "0,30"
seconds: "0"
then:
- switch.turn_off: mystrom_relay
- hours: "5-19"
minutes: "27,57"
seconds: "0"
then:
- switch.turn_on: mystrom_relay