mirror of
https://github.com/esphome/esphome.git
synced 2026-10-19 04:32:50 +00:00
Compare commits
4
Commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
1d2d359278 | ||
|
|
90cb333b0e | ||
|
|
b50cd757f0 | ||
|
|
ae3f98aadb |
@@ -1,7 +1,7 @@
|
||||
#include "bme680_bsec.h"
|
||||
#include "esphome/core/helpers.h"
|
||||
#include "esphome/core/log.h"
|
||||
#include <string>
|
||||
#include "esphome/core/progmem.h"
|
||||
|
||||
namespace esphome::bme680_bsec {
|
||||
#ifdef USE_BSEC
|
||||
@@ -9,7 +9,7 @@ ESPHOME_LOG_TAG(TAG, "bme680_bsec.sensor");
|
||||
|
||||
static constexpr uint32_t READ_TIMEOUT_ID = 0;
|
||||
|
||||
static const std::string IAQ_ACCURACY_STATES[4] = {"Stabilizing", "Uncertain", "Calibrating", "Calibrated"};
|
||||
PROGMEM_STRING_TABLE(IaqAccuracyStrings, "Stabilizing", "Uncertain", "Calibrating", "Calibrated");
|
||||
|
||||
std::vector<BME680BSECComponent *>
|
||||
BME680BSECComponent::instances; // NOLINT(cppcoreguidelines-avoid-non-const-global-variables)
|
||||
@@ -391,10 +391,15 @@ void BME680BSECComponent::publish_(const bsec_output_t *outputs, uint8_t num_out
|
||||
switch (outputs[i].sensor_id) {
|
||||
case BSEC_OUTPUT_IAQ:
|
||||
case BSEC_OUTPUT_STATIC_IAQ: {
|
||||
uint8_t accuracy = std::min<uint8_t>(outputs[i].accuracy, std::size(IAQ_ACCURACY_STATES) - 1);
|
||||
uint8_t accuracy = std::min<uint8_t>(outputs[i].accuracy, IaqAccuracyStrings::LAST_INDEX);
|
||||
this->queue_push_([this, signal]() { this->publish_sensor_(this->iaq_sensor_, signal); });
|
||||
this->queue_push_([this, accuracy]() {
|
||||
this->publish_sensor_(this->iaq_accuracy_text_sensor_, IAQ_ACCURACY_STATES[accuracy]);
|
||||
char text[IaqAccuracyStrings::MAX_LENGTH + 1];
|
||||
ESPHOME_strncpy_P(text,
|
||||
reinterpret_cast<ESPHOME_PGM_P>(
|
||||
IaqAccuracyStrings::get_progmem_str(accuracy, IaqAccuracyStrings::LAST_INDEX)),
|
||||
sizeof(text));
|
||||
this->publish_sensor_(this->iaq_accuracy_text_sensor_, text);
|
||||
});
|
||||
this->queue_push_([this, accuracy]() { this->publish_sensor_(this->iaq_accuracy_sensor_, accuracy, true); });
|
||||
|
||||
@@ -440,7 +445,7 @@ void BME680BSECComponent::publish_sensor_(sensor::Sensor *sensor, float value, b
|
||||
sensor->publish_state(value);
|
||||
}
|
||||
|
||||
void BME680BSECComponent::publish_sensor_(text_sensor::TextSensor *sensor, const std::string &value) {
|
||||
void BME680BSECComponent::publish_sensor_(text_sensor::TextSensor *sensor, const char *value) {
|
||||
if (!sensor || (sensor->has_state() && sensor->state == value)) {
|
||||
return;
|
||||
}
|
||||
|
||||
@@ -77,7 +77,7 @@ class BME680BSECComponent final : public Component, public i2c::I2CDevice {
|
||||
int64_t get_time_ns_();
|
||||
|
||||
void publish_sensor_(sensor::Sensor *sensor, float value, bool change_only = false);
|
||||
void publish_sensor_(text_sensor::TextSensor *sensor, const std::string &value);
|
||||
void publish_sensor_(text_sensor::TextSensor *sensor, const char *value);
|
||||
|
||||
void snapshot_state_(); // Fetch the current BSEC library state and save it in the bsec_state_data_ member (volatile
|
||||
// memory)
|
||||
|
||||
@@ -1,7 +1,6 @@
|
||||
#include "ezo_pmp.h"
|
||||
#include "esphome/core/log.h"
|
||||
#include "esphome/core/hal.h"
|
||||
#include "esphome/core/progmem.h"
|
||||
|
||||
namespace esphome::ezo_pmp {
|
||||
|
||||
@@ -32,24 +31,11 @@ static const uint16_t EZO_PMP_COMMAND_READ_ABSOLUTE_TOTAL_VOLUME_DOSED = 65;
|
||||
static const uint16_t EZO_PMP_COMMAND_READ_CALIBRATION_STATUS = 129;
|
||||
static const uint16_t EZO_PMP_COMMAND_READ_PUMP_VOLTAGE = 257;
|
||||
|
||||
enum DosingMode : uint8_t {
|
||||
DOSING_MODE_NONE,
|
||||
DOSING_MODE_VOLUME,
|
||||
DOSING_MODE_VOLUME_OVER_TIME,
|
||||
DOSING_MODE_CONSTANT_FLOW_RATE,
|
||||
DOSING_MODE_CONTINUOUS,
|
||||
};
|
||||
PROGMEM_STRING_TABLE(DosingModeStrings, "None", "Volume", "Volume/Time", "Constant Flow Rate", "Continuous");
|
||||
|
||||
static void publish_dosing_mode(text_sensor::TextSensor *sensor, DosingMode mode) {
|
||||
if (sensor == nullptr)
|
||||
return;
|
||||
char text[DosingModeStrings::MAX_LENGTH + 1];
|
||||
ESPHOME_strncpy_P(text, reinterpret_cast<ESPHOME_PGM_P>(DosingModeStrings::get_progmem_str(mode, DOSING_MODE_NONE)),
|
||||
sizeof(text));
|
||||
if (sensor->state != text)
|
||||
sensor->publish_state(text);
|
||||
}
|
||||
static const std::string DOSING_MODE_NONE = "None";
|
||||
static const std::string DOSING_MODE_VOLUME = "Volume";
|
||||
static const std::string DOSING_MODE_VOLUME_OVER_TIME = "Volume/Time";
|
||||
static const std::string DOSING_MODE_CONSTANT_FLOW_RATE = "Constant Flow Rate";
|
||||
static const std::string DOSING_MODE_CONTINUOUS = "Continuous";
|
||||
|
||||
void EzoPMP::dump_config() {
|
||||
LOG_I2C_DEVICE(this);
|
||||
@@ -216,7 +202,8 @@ void EzoPMP::read_command_result_() {
|
||||
|
||||
if (!this->is_dosing_flag_ && !this->is_paused_flag_) {
|
||||
// If pump is not paused and not dispensing
|
||||
publish_dosing_mode(this->dosing_mode_, DOSING_MODE_NONE);
|
||||
if (this->dosing_mode_ && this->dosing_mode_->state != DOSING_MODE_NONE)
|
||||
this->dosing_mode_->publish_state(DOSING_MODE_NONE);
|
||||
}
|
||||
|
||||
break;
|
||||
@@ -272,26 +259,31 @@ void EzoPMP::read_command_result_() {
|
||||
// Non-Read Commands
|
||||
|
||||
case EZO_PMP_COMMAND_DOSE_VOLUME: // Volume Dispensing (page 55)
|
||||
publish_dosing_mode(this->dosing_mode_, DOSING_MODE_VOLUME);
|
||||
if (this->dosing_mode_ && this->dosing_mode_->state != DOSING_MODE_VOLUME)
|
||||
this->dosing_mode_->publish_state(DOSING_MODE_VOLUME);
|
||||
break;
|
||||
|
||||
case EZO_PMP_COMMAND_DOSE_VOLUME_OVER_TIME: // Dose over time (page 56)
|
||||
publish_dosing_mode(this->dosing_mode_, DOSING_MODE_VOLUME_OVER_TIME);
|
||||
if (this->dosing_mode_ && this->dosing_mode_->state != DOSING_MODE_VOLUME_OVER_TIME)
|
||||
this->dosing_mode_->publish_state(DOSING_MODE_VOLUME_OVER_TIME);
|
||||
break;
|
||||
|
||||
case EZO_PMP_COMMAND_DOSE_WITH_CONSTANT_FLOW_RATE: // Constant Flow Rate (page 57)
|
||||
publish_dosing_mode(this->dosing_mode_, DOSING_MODE_CONSTANT_FLOW_RATE);
|
||||
if (this->dosing_mode_ && this->dosing_mode_->state != DOSING_MODE_CONSTANT_FLOW_RATE)
|
||||
this->dosing_mode_->publish_state(DOSING_MODE_CONSTANT_FLOW_RATE);
|
||||
break;
|
||||
|
||||
case EZO_PMP_COMMAND_DOSE_CONTINUOUSLY: // Continuous Dispensing (page 54)
|
||||
publish_dosing_mode(this->dosing_mode_, DOSING_MODE_CONTINUOUS);
|
||||
if (this->dosing_mode_ && this->dosing_mode_->state != DOSING_MODE_CONTINUOUS)
|
||||
this->dosing_mode_->publish_state(DOSING_MODE_CONTINUOUS);
|
||||
break;
|
||||
|
||||
case EZO_PMP_COMMAND_STOP_DOSING: // Stop (page 62)
|
||||
this->is_paused_flag_ = false;
|
||||
if (this->is_paused_)
|
||||
this->is_paused_->publish_state(this->is_paused_flag_);
|
||||
publish_dosing_mode(this->dosing_mode_, DOSING_MODE_NONE);
|
||||
if (this->dosing_mode_ && this->dosing_mode_->state != DOSING_MODE_NONE)
|
||||
this->dosing_mode_->publish_state(DOSING_MODE_NONE);
|
||||
break;
|
||||
|
||||
case EZO_PMP_COMMAND_EXEC_ARBITRARY_COMMAND_ADDRESS:
|
||||
|
||||
Reference in New Issue