Merge branch 'wifi_roam' into integration

This commit is contained in:
J. Nick Koston
2026-01-02 23:24:41 -10:00
6 changed files with 10 additions and 10 deletions
+1 -1
View File
@@ -1554,7 +1554,7 @@ void WiFiComponent::clear_all_bssid_priorities_() {
/// Clear BSSID priority tracking if all priorities are at minimum (saves memory)
/// At minimum priority, all BSSIDs are equally bad, so priority tracking is useless
/// Called after successful connection or after failed connection attempts
/// Called after failed connection attempts
void WiFiComponent::clear_priorities_if_all_min_() {
if (this->sta_priorities_.empty()) {
return;
+1 -1
View File
@@ -662,7 +662,7 @@ class WiFiComponent : public Component {
bool skip_cooldown_next_cycle_{false};
bool post_connect_roaming_{true}; // Enabled by default
bool roaming_scan_active_{false};
bool roaming_connect_active_{false}; // True during roaming connection attempt (skip priority decrease on fail)
bool roaming_connect_active_{false}; // True during roaming connection attempt (preserves roaming_attempts_)
#if defined(USE_ESP32) && defined(USE_WIFI_RUNTIME_POWER_SAVE)
WiFiPowerSaveMode configured_power_save_{WIFI_POWER_SAVE_NONE};
bool is_high_performance_mode_{false};
+2 -2
View File
@@ -12,10 +12,10 @@ platformio==6.1.18 # When updating platformio, also update /docker/Dockerfile
esptool==5.1.0
click==8.1.7
esphome-dashboard==20251013.0
aioesphomeapi==43.9.1
aioesphomeapi==43.10.0
zeroconf==0.148.0
puremagic==1.30
ruamel.yaml==0.18.17 # dashboard_import
ruamel.yaml==0.19.1 # dashboard_import
ruamel.yaml.clib==0.2.15 # dashboard_import
esphome-glyphsets==0.2.0
pillow==11.3.0
+1 -1
View File
@@ -41,7 +41,7 @@ sensor:
switch:
- platform: micronova
stove:
name: Stove on/off
name: Stove
text_sensor:
- platform: micronova
+4 -4
View File
@@ -92,7 +92,7 @@ sensor:
ch_pump_starts:
name: "Boiler Number of starts CH pump"
dhw_pump_valve_starts:
name: "Boiler Number of starts DHW pump/valve"
name: "Boiler Number of starts DHW pump valve"
dhw_burner_starts:
name: "Boiler Number of starts burner during DHW mode"
burner_operation_hours:
@@ -139,7 +139,7 @@ binary_sensor:
dhw_present:
name: "Boiler DHW present"
control_type_on_off:
name: "Boiler Control type is on/off"
name: "Boiler Control type is on-off"
cooling_supported:
name: "Boiler Cooling supported"
dhw_storage_tank:
@@ -153,9 +153,9 @@ binary_sensor:
max_ch_setpoint_transfer_enabled:
name: "Boiler CH maximum setpoint transfer enabled"
dhw_setpoint_rw:
name: "Boiler DHW setpoint read/write"
name: "Boiler DHW setpoint read-write"
max_ch_setpoint_rw:
name: "Boiler CH maximum setpoint read/write"
name: "Boiler CH maximum setpoint read-write"
switch:
- platform: opentherm
+1 -1
View File
@@ -1,4 +1,4 @@
climate:
- platform: zhlt01
name: ZH/LT-01 Climate
name: ZH-LT-01 Climate
transmitter_id: xmitr