mirror of
https://github.com/esphome/esphome.git
synced 2026-08-22 22:26:21 +00:00
Initialize the scan window once per build flavor
This commit is contained in:
@@ -263,14 +263,15 @@ void ESP32BLETracker::start_scan_(bool first) {
|
||||
this->scan_params_.own_addr_type = BLE_ADDR_TYPE_PUBLIC;
|
||||
this->scan_params_.scan_filter_policy = BLE_SCAN_FILTER_ALLOW_ALL;
|
||||
this->scan_params_.scan_interval = this->scan_interval_;
|
||||
uint32_t window = this->scan_window_;
|
||||
#ifdef ESPHOME_ESP32_BLE_TRACKER_CLIENT_COUNT
|
||||
// Count fresh: an automation can start a scan before loop() refreshes the counts.
|
||||
window = this->desired_scan_window_(this->count_client_states_().active);
|
||||
const uint32_t window = this->desired_scan_window_(this->count_client_states_().active);
|
||||
if (window != this->scan_window_) {
|
||||
// Guarantee the connection airtime instead of scanning wall to wall.
|
||||
ESP_LOGV(TAG, "Connection active, using %" PRIu32 " unit scan window", window);
|
||||
}
|
||||
#else
|
||||
const uint32_t window = this->scan_window_;
|
||||
#endif
|
||||
this->scan_params_.scan_window = window;
|
||||
|
||||
|
||||
Reference in New Issue