esphome:
|
|
name: watermeter
|
|
friendly_name: "Water meter"
|
|
area: "Laundry"
|
|
|
|
project:
|
|
name: dasfoo.watermeter
|
|
version: "1.0"
|
|
|
|
packages:
|
|
device_base: !include templates/esp8266.yaml
|
|
sensor: !include templates/esp8266-vcc.yaml
|
|
|
|
sensor:
|
|
- platform: pulse_meter
|
|
# Our meter (USLF20) is rated Q3=4.0 (m3/h).
|
|
# The official one is rated 5.0 (assuming also Q3).
|
|
# There's no Q4 value available.
|
|
#
|
|
# 3600 / 5000 = 0.72 seconds per liter. That's the shortest
|
|
# pulse length at a normal flow rate for the meter. Assuming
|
|
# 5x worst case, take 100ms as a reasonable margin.
|
|
internal_filter: 100ms
|
|
# Assuming Q1=70 (l/h), a flow with 52 second between pulses
|
|
# is beyond the measuring capabilities.
|
|
timeout: 1min
|
|
pin:
|
|
number: D2
|
|
inverted: true
|
|
mode:
|
|
input: true
|
|
pullup: true
|
|
|
|
name: "Incoming water flow"
|
|
unit_of_measurement: "L/min"
|
|
state_class: "measurement"
|
|
|
|
total:
|
|
name: "Incoming water total"
|
|
unit_of_measurement: "L"
|
|
device_class: "water"
|
|
state_class: "total_increasing"
|