esphome:
|
|
name: heating
|
|
friendly_name: "Heating"
|
|
area: "Workshop"
|
|
|
|
# The entire setup consists of:
|
|
#
|
|
# - Furnace that burns oil and produces heat.
|
|
# It only burns when necessary, i.e. some of the
|
|
# controlled temperatures are below set values.
|
|
#
|
|
# r/o: active (burning) / inactive (idle).
|
|
#
|
|
# - Boiler which keeps hot water (but can also heat it
|
|
# electrically, albeit turned on/off at the mains).
|
|
#
|
|
# r/o: temperature.
|
|
#
|
|
# - Floor heating which is technically controlled
|
|
# via furnace control panel, but is a separate system.
|
|
# It also includes two radiators (which are normally off),
|
|
# but due to ambiguity of "heating" meaning both the process
|
|
# and a house-warming system, we opt in for this specific
|
|
# "floor heating" term.
|
|
#
|
|
# r/o: flow temperature.
|
|
# r/o: active (flow temperature controlled) / inactive (idle).
|
|
# r/w: mode (instruct the flow to start heating).
|
|
|
|
project:
|
|
name: dasfoo.heating
|
|
version: "2.0"
|
|
|
|
on_boot:
|
|
then:
|
|
- if:
|
|
condition:
|
|
switch.is_off: relay_temperature_manual
|
|
then:
|
|
- select.set:
|
|
id: floor_mode
|
|
option: "auto"
|
|
else:
|
|
- if:
|
|
condition:
|
|
switch.is_on: relay_temperature_warm
|
|
then:
|
|
- select.set:
|
|
id: floor_mode
|
|
option: "off"
|
|
else:
|
|
- select.set:
|
|
id: floor_mode
|
|
option: "on"
|
|
|
|
packages:
|
|
device_base: !include templates/esp32.yaml
|
|
|
|
i2c:
|
|
sda: GPIO21
|
|
# Marked as SCK on the display itself for some reason,
|
|
# thus the GPIO choice.
|
|
scl: GPIO18
|
|
|
|
font:
|
|
- file: "fonts/DejaVuSans.ttf"
|
|
id: font_sans
|
|
size: 20
|
|
|
|
display:
|
|
- platform: ssd1306_i2c
|
|
model: "SSD1306 128x32"
|
|
id: oled_display
|
|
lambda: |-
|
|
it.printf(
|
|
4, 6,
|
|
id(font_sans),
|
|
"%.2f C",
|
|
id(boiler_temperature).state);
|
|
|
|
if (id(furnace_burning).state) {
|
|
it.filled_circle(112, 16, 12);
|
|
} else {
|
|
it.circle(112, 16, 12);
|
|
}
|
|
|
|
one_wire:
|
|
- platform: gpio
|
|
pin: GPIO27
|
|
|
|
sensor:
|
|
- platform: dallas_temp
|
|
address: 0x133c2cf648f40728
|
|
id: boiler_temperature
|
|
name: "Boiler temperature"
|
|
filters:
|
|
- offset: 0.5
|
|
|
|
- platform: dallas_temp
|
|
address: 0x4845b7211864ff28
|
|
id: hot_water_temperature
|
|
name: "Hot water temperature"
|
|
|
|
- platform: dallas_temp
|
|
address: 0x6a0316643959ff28
|
|
id: floor_temperature
|
|
name: "Floor temperature"
|
|
|
|
- platform: adc
|
|
pin: GPIO32
|
|
update_interval: 1s
|
|
id: furnace_burning_led_brightness
|
|
attenuation: auto
|
|
# Make voltage value available in UI for debugging and history.
|
|
name: "Furnace burning - LED brightness"
|
|
entity_category: diagnostic
|
|
disabled_by_default: true
|
|
|
|
- platform: adc
|
|
pin: GPIO33
|
|
update_interval: 1s
|
|
id: floor_active_led_brightness
|
|
attenuation: auto
|
|
# Make voltage value available in UI for debugging and history.
|
|
name: "Floor active - LED brightness"
|
|
entity_category: diagnostic
|
|
disabled_by_default: true
|
|
|
|
binary_sensor:
|
|
- platform: analog_threshold
|
|
id: furnace_burning
|
|
name: "Furnace burning"
|
|
sensor_id: furnace_burning_led_brightness
|
|
# The reading (V) gets lower as brightness increases. Keep the threshold
|
|
# low (close to LED reading) to avoid triggering with a lamp or natural light.
|
|
threshold: 2.2 # LED on = 1.93V, flashlight on = 2.5V.
|
|
filters:
|
|
- invert:
|
|
|
|
- platform: analog_threshold
|
|
id: heating_enabled
|
|
name: "Floor active"
|
|
sensor_id: floor_active_led_brightness
|
|
# This sensor is more exposed to external light due to construction.
|
|
threshold: 1.9 # LED on = 1.76V, flashlight on = 2.1V.
|
|
filters:
|
|
- invert:
|
|
|
|
switch:
|
|
- platform: gpio
|
|
pin: GPIO25
|
|
id: relay_temperature_manual
|
|
inverted: true
|
|
restore_mode: RESTORE_DEFAULT_OFF
|
|
|
|
- platform: gpio
|
|
pin: GPIO26
|
|
id: relay_temperature_warm
|
|
inverted: true
|
|
restore_mode: RESTORE_DEFAULT_OFF
|
|
|
|
select:
|
|
- platform: template
|
|
name: "Floor mode"
|
|
id: floor_mode
|
|
options:
|
|
- "on"
|
|
- "off"
|
|
- "auto"
|
|
optimistic: true
|
|
set_action:
|
|
lambda: |-
|
|
if (x == "auto") {
|
|
id(relay_temperature_manual).turn_off();
|
|
} else {
|
|
if (x == "off") {
|
|
id(relay_temperature_warm).turn_on();
|
|
} else {
|
|
id(relay_temperature_warm).turn_off();
|
|
}
|
|
id(relay_temperature_manual).turn_on();
|
|
}
|