substitutions:
name: "car-charger"
friendly_name: "Car charger"
esphome:
area: "Garage"
packages:
device_base: !include templates/mystrom.yaml
time: !include templates/time.yaml
switch:
- platform: template
name: "Failsafe schedule"
id: failsafe_schedule
restore_mode: RESTORE_DEFAULT_ON
optimistic: true
time:
- platform: sntp
id: sntp_time
servers: !secret sntp_servers
timezone: Europe/Zurich
on_time:
- seconds: 0
minutes: 1
hours: 0-6,19-23
then:
- if:
condition:
- switch.is_on: failsafe_schedule
- switch.is_off: mystrom_relay
then:
- logger.log: >-
Power relay is off during T2, assuming automation failure and
correcting
- switch.turn_on: mystrom_relay