esphome: name: watermeter friendly_name: "Water meter" area: "Laundry" project: name: dasfoo.watermeter version: "1.0" packages: device_base: !include templates/esp8266.yaml sensor: !include templates/esp8266-vcc.yaml sensor: - platform: pulse_meter # Our meter (USLC/20) is rated Qmax=5.0 (m3/h). # The official one is rated 5.0. # # 3600 / 5000 = 0.72 seconds per liter. That's the shortest # pulse length at a maximum flow rate for the meter. internal_filter: 720ms # Assuming Qmin=50 (l/h), a flow with >72 seconds between pulses # is beyond the measuring capabilities. However, one of the # irrigation valves only consumes 0.73 L/min, so we push it a bit. timeout: 90s pin: number: D2 inverted: true mode: input: true pullup: true name: "Incoming water flow" unit_of_measurement: "L/min" device_class: volume_flow_rate state_class: "measurement" icon: mdi:pipe-valve # device_class? total: name: "Incoming water total" unit_of_measurement: "L" device_class: "water" state_class: "total_increasing"