diff --git a/images1/Bosch/ota_t0x300a_m0x1209_v0x36081514.ota b/images1/Bosch/ota_t0x300a_m0x1209_v0x36081514.ota deleted file mode 100644 index 91e1374..0000000 Binary files a/images1/Bosch/ota_t0x300a_m0x1209_v0x36081514.ota and /dev/null differ diff --git a/images/Bosch/ota_t0x300a_m0x1209_v0x37041514.ota b/images1/Bosch/ota_t0x300a_m0x1209_v0x37041514.ota similarity index 100% rename from images/Bosch/ota_t0x300a_m0x1209_v0x37041514.ota rename to images1/Bosch/ota_t0x300a_m0x1209_v0x37041514.ota diff --git a/index.json b/index.json index 50c5a0d..0a85d9e 100644 --- a/index.json +++ b/index.json @@ -40,18 +40,6 @@ "otaHeaderString": "PLUG_EU", "modelId": "RBSH-SP-ZB-EU" }, - { - "fileName": "ota_t0x300a_m0x1209_v0x37041514.ota", - "fileVersion": 923014420, - "fileSize": 168518, - "url": "https://raw.githubusercontent.com/Koenkk/zigbee-OTA/master/images/Bosch/ota_t0x300a_m0x1209_v0x37041514.ota", - "imageType": 12298, - "manufacturerCode": 4617, - "sha512": "834531102c17686c831a3e0e0b78b402643a50c42264fa326fbe32213a0c104bc036befcdf51f330cbbf5c6c95d38a028365c3bbaf7feaa453e4d11792f79f36", - "otaHeaderString": "RBSH-TRV0-ZB-EU", - "modelId": "RBSH-TRV0-ZB-EU", - "releaseNotes": "1. Fix error E03, which can happen on some radiators after some time" - }, { "fileName": "12128_OTA_3.18.ZIGBEE", "fileVersion": 318, @@ -7776,5 +7764,17 @@ "manufacturerName": [ "_TZ3000_x3ewpzyr" ] + }, + { + "fileName": "ota_t0x300a_m0x1209_v0x37061514.ota", + "fileVersion": 923145492, + "fileSize": 168588, + "url": "https://raw.githubusercontent.com/Koenkk/zigbee-OTA/master/images/Bosch/ota_t0x300a_m0x1209_v0x37061514.ota", + "imageType": 12298, + "manufacturerCode": 4617, + "sha512": "d8c7f60a98f36580a70be3d67ed62272109d5631de7535f47db8af70a049d501aed95b95fe6f651036fd1b6cc26c6dc71cd46952a12291c051032c07506222c0", + "otaHeaderString": "RBSH-TRV0-ZB-EU", + "modelId": "RBSH-TRV0-ZB-EU", + "releaseNotes": "1. A fault has been resolved that caused the radiator thermostat to sometimes enter an endless loop during auto-calibration" } ] \ No newline at end of file diff --git a/index1.json b/index1.json index 72e6522..c2831c3 100644 --- a/index1.json +++ b/index1.json @@ -1,15 +1,4 @@ [ - { - "fileName": "ota_t0x300a_m0x1209_v0x36081514.ota", - "fileVersion": 906499348, - "fileSize": 168427, - "url": "https://raw.githubusercontent.com/Koenkk/zigbee-OTA/master/images1/Bosch/ota_t0x300a_m0x1209_v0x36081514.ota", - "imageType": 12298, - "manufacturerCode": 4617, - "sha512": "ce5794daa1db129018229d15a4c7340ff2181fdf1374a6c17b7209d2d4a9c48edd7de747298eed5ce6e4862cb7cb706feaf0dc58155984b64bdc02c3f70ff5fc", - "otaHeaderString": "RBSH-TRV0-ZB-EU", - "modelId": "RBSH-TRV0-ZB-EU" - }, { "fileName": "100B-0111-01001A00-ConfLight-ModuLum-EFR32MG13.zigbee", "fileVersion": 16783872, @@ -1592,5 +1581,17 @@ "sha512": "e3e4d75124c74d0595af42e9371b590098d63e86bbda515ca9a309c39894388d8fcf378969c1038d57806809464aa8a975e4f32a18d1f6836605252b58f1a9ea", "otaHeaderString": "VZM30-SN_OnOff", "originalUrl": "https://files.inovelli.com/firmware/VZM30-SN/Beta/0.03/VZM30-SN_0.03.ota" + }, + { + "fileName": "ota_t0x300a_m0x1209_v0x37041514.ota", + "fileVersion": 923014420, + "fileSize": 168518, + "url": "https://raw.githubusercontent.com/Koenkk/zigbee-OTA/master/images1/Bosch/ota_t0x300a_m0x1209_v0x37041514.ota", + "imageType": 12298, + "manufacturerCode": 4617, + "sha512": "834531102c17686c831a3e0e0b78b402643a50c42264fa326fbe32213a0c104bc036befcdf51f330cbbf5c6c95d38a028365c3bbaf7feaa453e4d11792f79f36", + "otaHeaderString": "RBSH-TRV0-ZB-EU", + "modelId": "RBSH-TRV0-ZB-EU", + "releaseNotes": "1. Fix error E03, which can happen on some radiators after some time" } ] \ No newline at end of file