"""Config validation for custom_pdu and the deprecated custom_command alias.
|
|
|
|
custom_command took a raw frame with a leading device address byte; custom_pdu takes the PDU only.
|
|
Most of these tests cover what the schema itself enforces (the two keys are mutually exclusive, and
|
|
custom_pdu takes byte-sized values). The last two reach the final-validate step that a bare-schema
|
|
test cannot: a write-coded custom_pdu polled continuously is rejected there.
|
|
"""
|
|
|
|
import pytest
|
|
from voluptuous import Invalid, MultipleInvalid
|
|
|
|
from esphome.components.modbus_controller import (
|
|
ModbusItemBaseSchema,
|
|
validate_custom_pdu_item,
|
|
)
|
|
from esphome.components.modbus_controller.const import (
|
|
CONF_CUSTOM_COMMAND,
|
|
CONF_CUSTOM_PDU,
|
|
CONF_MODBUS_CONTROLLER_ID,
|
|
)
|
|
from esphome.config import Config
|
|
from esphome.const import CONF_ADDRESS, CONF_CONTINUOUS, CONF_ID
|
|
from esphome.core import ID
|
|
import esphome.final_validate as fv
|
|
|
|
|
|
def test_custom_command_accepted_at_schema_level() -> None:
|
|
"""custom_command validates at the schema level; migration/rejection happens in final validate."""
|
|
config = ModbusItemBaseSchema(
|
|
{CONF_CUSTOM_COMMAND: [0x01, 0x03, 0x00, 0x2A, 0x00, 0x01]}
|
|
)
|
|
assert config[CONF_CUSTOM_COMMAND] == [0x01, 0x03, 0x00, 0x2A, 0x00, 0x01]
|
|
|
|
|
|
def test_custom_pdu_and_custom_command_mutually_exclusive() -> None:
|
|
"""Only one custom source may be given; supplying both is a schema error."""
|
|
with pytest.raises((Invalid, MultipleInvalid)):
|
|
ModbusItemBaseSchema(
|
|
{
|
|
CONF_CUSTOM_PDU: [0x03, 0x00, 0x2A, 0x00, 0x01],
|
|
CONF_CUSTOM_COMMAND: [0x01, 0x03, 0x00, 0x2A, 0x00, 0x01],
|
|
}
|
|
)
|
|
|
|
|
|
def test_custom_pdu_accepted() -> None:
|
|
"""The new key takes PDU bytes (function code + data, no address byte)."""
|
|
config = ModbusItemBaseSchema({CONF_CUSTOM_PDU: [0x03, 0x00, 0x2A, 0x00, 0x01]})
|
|
assert config[CONF_CUSTOM_PDU] == [0x03, 0x00, 0x2A, 0x00, 0x01]
|
|
|
|
|
|
def test_custom_pdu_rejects_non_byte_values() -> None:
|
|
"""PDU entries are bytes; a word-sized value is a sign the old raw format is being used."""
|
|
with pytest.raises((Invalid, MultipleInvalid)):
|
|
ModbusItemBaseSchema({CONF_CUSTOM_PDU: [0x0103, 0x002A]})
|
|
|
|
|
|
def _controller_full_config(*, continuous: bool) -> Config:
|
|
"""A minimal full-config graph with one modbus_controller declaring id 'ctl', enough for the
|
|
final-validate to resolve the controller (and its continuous flag) from an item's
|
|
modbus_controller_id."""
|
|
ctl_id = ID("ctl", is_declaration=True)
|
|
config = Config()
|
|
config["modbus_controller"] = [
|
|
{CONF_ID: ctl_id, CONF_ADDRESS: 1, CONF_CONTINUOUS: continuous}
|
|
]
|
|
config.declare_ids.append((ctl_id, ["modbus_controller", 0, CONF_ID]))
|
|
return config
|
|
|
|
|
|
@pytest.fixture
|
|
def reset_full_config():
|
|
token = fv.full_config.set(Config())
|
|
yield
|
|
fv.full_config.reset(token)
|
|
|
|
|
|
def test_continuous_write_custom_pdu_rejected(reset_full_config) -> None:
|
|
"""A write-coded custom_pdu (0x17 = read/write-multiple) under a continuous controller is
|
|
rejected at final validate: the hub would strip continuous from the mutating code and warn on
|
|
every update."""
|
|
fv.full_config.set(_controller_full_config(continuous=True))
|
|
with pytest.raises(Invalid, match="can't be polled continuously"):
|
|
validate_custom_pdu_item(
|
|
{
|
|
CONF_MODBUS_CONTROLLER_ID: ID("ctl"),
|
|
CONF_CUSTOM_PDU: [0x17, 0x00, 0x03, 0x00, 0x01],
|
|
}
|
|
)
|
|
|
|
|
|
def test_continuous_read_custom_pdu_allowed(reset_full_config) -> None:
|
|
"""A read-coded custom_pdu (0x03) under a continuous controller is fine - only writes stream."""
|
|
fv.full_config.set(_controller_full_config(continuous=True))
|
|
validate_custom_pdu_item(
|
|
{
|
|
CONF_MODBUS_CONTROLLER_ID: ID("ctl"),
|
|
CONF_CUSTOM_PDU: [0x03, 0x00, 0x2A, 0x00, 0x01],
|
|
}
|
|
)
|