Files
esphome/esphome/components/sm300d2/sensor.py
T

110 lines
3.9 KiB
Python

import esphome.codegen as cg
from esphome.components import sensor, uart
import esphome.config_validation as cv
from esphome.const import (
CONF_CO2,
CONF_FORMALDEHYDE,
CONF_HUMIDITY,
CONF_ID,
CONF_PM_2_5,
CONF_PM_10_0,
CONF_TEMPERATURE,
CONF_TVOC,
DEVICE_CLASS_CARBON_DIOXIDE,
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_PM10,
DEVICE_CLASS_PM25,
DEVICE_CLASS_TEMPERATURE,
DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS,
ICON_CHEMICAL_WEAPON,
ICON_FLASK,
ICON_GRAIN,
ICON_MOLECULE_CO2,
STATE_CLASS_MEASUREMENT,
UNIT_CELSIUS,
UNIT_MICROGRAMS_PER_CUBIC_METER,
UNIT_PARTS_PER_MILLION,
UNIT_PERCENT,
)
from esphome.types import ConfigType
DEPENDENCIES = ["uart"]
sm300d2_ns = cg.esphome_ns.namespace("sm300d2")
SM300D2Sensor = sm300d2_ns.class_("SM300D2Sensor", cg.PollingComponent, uart.UARTDevice)
CONFIG_SCHEMA = cv.All(
cv.Schema(
{
cv.GenerateID(): cv.declare_id(SM300D2Sensor),
cv.Optional(CONF_CO2): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_MILLION,
icon=ICON_MOLECULE_CO2,
accuracy_decimals=0,
device_class=DEVICE_CLASS_CARBON_DIOXIDE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_FORMALDEHYDE): sensor.sensor_schema(
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
icon=ICON_FLASK,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_TVOC): sensor.sensor_schema(
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
icon=ICON_CHEMICAL_WEAPON,
accuracy_decimals=0,
device_class=DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_PM_2_5): sensor.sensor_schema(
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
icon=ICON_GRAIN,
accuracy_decimals=0,
device_class=DEVICE_CLASS_PM25,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_PM_10_0): sensor.sensor_schema(
unit_of_measurement=UNIT_MICROGRAMS_PER_CUBIC_METER,
icon=ICON_GRAIN,
accuracy_decimals=0,
device_class=DEVICE_CLASS_PM10,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=1,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
unit_of_measurement=UNIT_PERCENT,
accuracy_decimals=1,
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
),
}
)
.extend(cv.polling_component_schema("60s"))
.extend(uart.UART_DEVICE_SCHEMA)
)
FINAL_VALIDATE_SCHEMA = uart.final_validate_device_schema(
"sm300d2", baud_rate=9600, require_rx=True, data_bits=8, parity="NONE", stop_bits=1
)
async def to_code(config: ConfigType) -> None:
var = cg.new_Pvariable(config[CONF_ID])
await cg.register_component(var, config)
await uart.register_uart_device(var, config)
sensors = sensor.sub_sensors(config)
await sensors(CONF_CO2, var.set_co2_sensor)
await sensors(CONF_FORMALDEHYDE, var.set_formaldehyde_sensor)
await sensors(CONF_TVOC, var.set_tvoc_sensor)
await sensors(CONF_PM_2_5, var.set_pm_2_5_sensor)
await sensors(CONF_PM_10_0, var.set_pm_10_0_sensor)
await sensors(CONF_TEMPERATURE, var.set_temperature_sensor)
await sensors(CONF_HUMIDITY, var.set_humidity_sensor)