dlms_meter: id: dlms_meter_hub receive_timeout: 50ms decryption_key: "36C66639E48A8CA4D6BC8B282A793BBB" auth_key: "11223344556677889900AABBCCDDEEFF" skip_crc: true custom_patterns: - "custom_pattern_1" - "custom_pattern_2" - pattern: "L, TSTR" name: "MeterID" default_obis: "0.0.96.1.0.255" - pattern: "F, TDTM" name: "DateTime" default_obis: "0.0.1.0.0.255" sensor: - platform: dlms_meter obis_code: "1.0.32.7.0.255" name: "Voltage L1" unit_of_measurement: V accuracy_decimals: 1 device_class: voltage state_class: measurement - platform: dlms_meter obis_code: "1.0.1.8.0.255" name: "Active energy taken from grid" unit_of_measurement: Wh device_class: energy state_class: total_increasing - platform: dlms_meter dlms_meter_id: dlms_meter_hub obis_code: "1-0:99.99.9" name: "Custom Dynamic Sensor" text_sensor: - platform: dlms_meter obis_code: "0.0.1.0.0.255" name: "timestamp" - platform: dlms_meter dlms_meter_id: dlms_meter_hub obis_code: "0-0:99.99.9" name: "Custom Dynamic Text Sensor" binary_sensor: - platform: dlms_meter dlms_meter_id: dlms_meter_hub obis_code: "0-1:2.3.4" name: "Custom Binary Sensor"