dlms_meter: id: dlms_meter_hub receive_timeout: 50ms decryption_key: "36C66639E48A8CA4D6BC8B282A793BBB" auth_key: "11223344556677889900AABBCCDDEEFF" skip_crc: true provider: "netznoe" custom_patterns: - "custom_pattern_1" - "custom_pattern_2" sensor: # Old Schema tests - platform: dlms_meter voltage_l1: name: "Voltage L1" voltage_l2: name: "Voltage L2" voltage_l3: name: "Voltage L3" current_l1: name: "Current L1" current_l2: name: "Current L2" current_l3: name: "Current L3" active_power_plus: name: "Active power taken from grid" active_power_minus: name: "Active power put into grid" active_energy_plus: name: "Active energy taken from grid" active_energy_minus: name: "Active energy put into grid" reactive_energy_plus: name: "Reactive energy taken from grid" reactive_energy_minus: name: "Reactive energy put into grid" power_factor: name: "Power factor" # Dynamic Schema tests - platform: dlms_meter dlms_meter_id: dlms_meter_hub obis_code: "1-0:99.99.9" name: "Custom Dynamic Sensor" text_sensor: # Old Schema tests - platform: dlms_meter timestamp: name: "timestamp" meternumber: name: "Meter Number" # Dynamic Schema tests - platform: dlms_meter dlms_meter_id: dlms_meter_hub obis_code: "0-0:99.99.9" name: "Custom Dynamic Text Sensor" binary_sensor: # Dynamic Schema tests (Binary sensors only use the dynamic schema) - platform: dlms_meter dlms_meter_id: dlms_meter_hub obis_code: "0-1:2.3.4" name: "Custom Binary Sensor"