[modbus_controller] Rename custom_command to custom_pdu; reject address 0; retire skip_updates (#18652)
This commit is contained in:
@@ -14,7 +14,6 @@ ModbusCommandItem::ModbusCommandItem(ModbusController &controller, modbus::Modbu
|
||||
RegisterRange &&range)
|
||||
: modbus::ModbusClientDevice(parent, address),
|
||||
sensors(std::move(range.sensors)),
|
||||
skip_updates(range.skip_updates),
|
||||
register_type_(range.register_type),
|
||||
start_address_(range.start_address),
|
||||
register_count_(range.register_count),
|
||||
@@ -24,12 +23,14 @@ ModbusCommandItem::ModbusCommandItem(ModbusController &controller, modbus::Modbu
|
||||
ModbusCommandItem::ModbusCommandItem(ModbusController &controller, modbus::ModbusClientHub *parent, uint8_t address,
|
||||
SensorItem *sensor)
|
||||
: modbus::ModbusClientDevice(parent, address),
|
||||
skip_updates(sensor->skip_updates),
|
||||
start_address_(sensor->start_address),
|
||||
register_count_(sensor->register_count),
|
||||
function_code_(FunctionCode::CUSTOM),
|
||||
custom_data_(&sensor->custom_data),
|
||||
custom_pdu_(&sensor->custom_pdu),
|
||||
controller_(&controller) {
|
||||
// The PDU's first byte is its real function code; carry it so dump_config, the on_command_sent
|
||||
// trigger and the response callbacks report the actual code instead of CUSTOM.
|
||||
if (!sensor->custom_pdu.empty())
|
||||
this->function_code_ = static_cast<FunctionCode>(sensor->custom_pdu.data()[0]);
|
||||
this->sensors.insert(sensor);
|
||||
}
|
||||
|
||||
@@ -40,13 +41,12 @@ ModbusCommandItem::ModbusCommandItem(ModbusController &controller, modbus::Modbu
|
||||
ModbusCommandItem::ModbusCommandItem(const ModbusCommandItem &other)
|
||||
: modbus::ModbusClientDevice(other.parent_, other.address_),
|
||||
sensors(other.sensors),
|
||||
skip_updates(other.skip_updates),
|
||||
on_data_func(other.on_data_func),
|
||||
register_type_(other.register_type_),
|
||||
start_address_(other.start_address_),
|
||||
register_count_(other.register_count_),
|
||||
function_code_(other.function_code_),
|
||||
custom_data_(other.custom_data_),
|
||||
custom_pdu_(other.custom_pdu_),
|
||||
controller_(other.controller_) {
|
||||
// SmallInlineBuffer is move-only, so deep-copy the bytes explicitly.
|
||||
this->payload.set(other.payload.data(), other.payload.size());
|
||||
@@ -55,14 +55,13 @@ ModbusCommandItem::ModbusCommandItem(const ModbusCommandItem &other)
|
||||
ModbusCommandItem::ModbusCommandItem(ModbusCommandItem &&other) noexcept
|
||||
: modbus::ModbusClientDevice(other.parent_, other.address_),
|
||||
sensors(std::move(other.sensors)),
|
||||
skip_updates(other.skip_updates),
|
||||
on_data_func(std::move(other.on_data_func)),
|
||||
payload(std::move(other.payload)),
|
||||
register_type_(other.register_type_),
|
||||
start_address_(other.start_address_),
|
||||
register_count_(other.register_count_),
|
||||
function_code_(other.function_code_),
|
||||
custom_data_(other.custom_data_),
|
||||
custom_pdu_(other.custom_pdu_),
|
||||
controller_(other.controller_) {
|
||||
other.parent_ = nullptr;
|
||||
}
|
||||
@@ -74,11 +73,14 @@ void ModbusCommandItem::on_response(std::span<const uint8_t> request_pdu, std::s
|
||||
auto data = modbus::helpers::server_pdu_payload(response_pdu);
|
||||
if (this->on_data_func) {
|
||||
this->on_data_func(this->register_type_, this->start_address_, data);
|
||||
} else if (modbus::helpers::is_function_code_write(static_cast<uint8_t>(this->function_code_))) {
|
||||
// write acknowledgement - nothing to publish
|
||||
} else {
|
||||
} else if (!this->sensors.empty()) {
|
||||
// A polling command always has sensors; a factory/write command never does. Test this before the
|
||||
// write-code branch so a custom_pdu whose function code is a write (e.g. 0x17, whose response
|
||||
// carries read data) still reaches its sensor instead of being treated as a bare write ack.
|
||||
for (auto *sensor : this->sensors)
|
||||
sensor->parse_and_publish(data);
|
||||
} else if (modbus::helpers::is_function_code_write(static_cast<uint8_t>(this->function_code_))) {
|
||||
// write acknowledgement - nothing to publish
|
||||
}
|
||||
if (this->controller_ != nullptr)
|
||||
this->controller_->unqueue_command(this);
|
||||
@@ -116,13 +118,11 @@ void ModbusCommandItem::on_sent(std::span<const uint8_t> request_pdu) {
|
||||
// on_sent is this command's only callback, so drop the one-shot from the queue here, or it would leak.
|
||||
// Test the address the frame went to, not address_: a custom command's frame carries its own address
|
||||
// (frame[0]), which may differ from this controller's. (unqueue_command() is a no-op for a poll.)
|
||||
// A custom polling command sends its PDU to this controller's own address, so only a factory custom
|
||||
// command (a raw frame staged in payload) can carry a different address byte.
|
||||
uint8_t wire_address = this->address_;
|
||||
if (this->function_code_ == FunctionCode::CUSTOM) {
|
||||
std::span<const uint8_t> frame =
|
||||
this->custom_data_ != nullptr ? std::span<const uint8_t>(*this->custom_data_) : this->payload;
|
||||
if (!frame.empty())
|
||||
wire_address = frame[0];
|
||||
}
|
||||
if (this->function_code_ == FunctionCode::CUSTOM && !this->payload.empty())
|
||||
wire_address = this->payload.data()[0];
|
||||
if (wire_address == modbus::BROADCAST_ADDRESS)
|
||||
this->controller_->unqueue_command(this);
|
||||
}
|
||||
@@ -194,23 +194,11 @@ void ModbusController::sweep_completed_one_shots_() {
|
||||
[](const std::unique_ptr<ModbusCommandItem> &item) { return item->pending_removal; });
|
||||
}
|
||||
|
||||
void ModbusController::update_range_(ModbusCommandItem &cmd) {
|
||||
if (this->update_counter_ % (cmd.skip_updates + 1) != 0) {
|
||||
ESP_LOGVV(TAG, "Skipping update for range 0x%X", cmd.register_address());
|
||||
return;
|
||||
}
|
||||
// A refusal is already logged by the hub; note the affected range for controller-level diagnostics.
|
||||
if (!cmd.send()) {
|
||||
ESP_LOGD(TAG, "Poll refused by hub for range 0x%X", cmd.register_address());
|
||||
}
|
||||
}
|
||||
|
||||
void ModbusController::update() {
|
||||
this->sweep_completed_one_shots_(); // reclaim one-shots deferred out of their own callbacks
|
||||
if (this->module_offline_) {
|
||||
// Offline probing follows the offline cadence alone; per-range skip_updates resumes once the
|
||||
// device is back online. Requiring both cadences to coincide would leave phase combinations
|
||||
// where a probe never goes out.
|
||||
// Offline probing follows the offline cadence alone; regular every-update polling resumes once
|
||||
// the device is back online.
|
||||
if (offline_retry_due(this->update_counter_, this->module_offline_at_, this->offline_skip_updates_)) {
|
||||
ESP_LOGV(TAG, "Module offline - retrying");
|
||||
this->cmd_non_responses_ = 0; // allow the probe through can_send()
|
||||
@@ -229,7 +217,9 @@ void ModbusController::update() {
|
||||
if (this->can_send()) {
|
||||
for (auto &cmd : this->polling_command_items_) {
|
||||
ESP_LOGVV(TAG, "Updating range 0x%X", cmd.register_address());
|
||||
this->update_range_(cmd);
|
||||
// A refusal is already logged by the hub; note the affected range for controller-level diagnostics.
|
||||
if (!cmd.send())
|
||||
ESP_LOGD(TAG, "Poll refused by hub for range 0x%X", cmd.register_address());
|
||||
}
|
||||
}
|
||||
this->update_counter_++;
|
||||
@@ -264,8 +254,8 @@ void ModbusController::create_polling_commands_() {
|
||||
bool range_custom_size = false;
|
||||
SensorItem *prev = nullptr;
|
||||
for (SensorItem *curr : this->sensorset_) {
|
||||
ESP_LOGV(TAG, "Register: 0x%X count=%d size=%zu offset=%u skip=%u addr=%p", curr->start_address,
|
||||
curr->register_count, curr->get_register_size(), curr->offset, curr->skip_updates, curr);
|
||||
ESP_LOGV(TAG, "Register: 0x%X count=%d size=%zu offset=%u addr=%p", curr->start_address, curr->register_count,
|
||||
curr->get_register_size(), curr->offset, curr);
|
||||
|
||||
const bool custom_size = curr->get_register_size() != static_cast<size_t>(curr->register_count) * 2;
|
||||
|
||||
@@ -296,14 +286,12 @@ void ModbusController::create_polling_commands_() {
|
||||
ESP_LOGV(TAG, "Extend range to include 0x%X", curr->start_address);
|
||||
} else if (range_shared && !range_forced && curr->start_address >= r.start_address &&
|
||||
curr->start_address + curr->register_count <= r.start_address + r.register_count &&
|
||||
!range_custom_size && !custom_size && curr->skip_updates == r.skip_updates) {
|
||||
!range_custom_size && !custom_size) {
|
||||
// The registers already fall inside a range that a shared-address join widened, so this sensor
|
||||
// reads its slice of that response instead of adding an overlapping second poll. The guards keep
|
||||
// it narrow: only a widened range, never a force-isolated one; only where every register in the
|
||||
// range returns two bytes, so interior positions follow from the addresses; only sensors genuinely
|
||||
// inside it, which is why the lower bound is needed given the walk is not address-ordered; and
|
||||
// only where the polling rates already match, since joining runs this sensor through the rate
|
||||
// merge below and would otherwise change one of them.
|
||||
// inside it, which is why the lower bound is needed given the walk is not address-ordered.
|
||||
const uint16_t addr_delta = curr->start_address - r.start_address;
|
||||
curr->offset = static_cast<uint8_t>((curr->addresses_bits() ? addr_delta : addr_delta * 2) +
|
||||
curr->offset_from_start_address);
|
||||
@@ -329,7 +317,7 @@ void ModbusController::create_polling_commands_() {
|
||||
|
||||
if (!join) {
|
||||
if (have_range) {
|
||||
ESP_LOGV(TAG, "Add range 0x%X %d skip:%d", r.start_address, r.register_count, r.skip_updates);
|
||||
ESP_LOGV(TAG, "Add range 0x%X %d", r.start_address, r.register_count);
|
||||
this->create_polling_command_(std::move(r));
|
||||
}
|
||||
r = {};
|
||||
@@ -341,11 +329,7 @@ void ModbusController::create_polling_commands_() {
|
||||
r.start_address = curr->start_address;
|
||||
r.register_count = curr->register_count;
|
||||
r.register_type = curr->register_type;
|
||||
r.skip_updates = curr->skip_updates;
|
||||
have_range = true;
|
||||
} else if (curr->skip_updates != 0) {
|
||||
// use the lowest non-zero skip_updates for the whole range (0 is the default and is excluded)
|
||||
r.skip_updates = (r.skip_updates != 0) ? std::min(r.skip_updates, curr->skip_updates) : curr->skip_updates;
|
||||
}
|
||||
|
||||
// Every member records its range's first register. The resolved offset is relative to it, so the
|
||||
@@ -355,7 +339,7 @@ void ModbusController::create_polling_commands_() {
|
||||
prev = curr;
|
||||
}
|
||||
if (have_range) {
|
||||
ESP_LOGV(TAG, "Add last range 0x%X %d skip:%d", r.start_address, r.register_count, r.skip_updates);
|
||||
ESP_LOGV(TAG, "Add last range 0x%X %d", r.start_address, r.register_count);
|
||||
this->create_polling_command_(std::move(r));
|
||||
}
|
||||
// Reclaim growth slack; safe here because nothing has registered with the hub yet (see the
|
||||
@@ -380,8 +364,8 @@ void ModbusController::dump_config() {
|
||||
}
|
||||
ESP_LOGCONFIG(TAG, "ranges");
|
||||
for (auto &it : this->polling_command_items_) {
|
||||
ESP_LOGCONFIG(TAG, " Range type=%u start=0x%X count=%d skip_updates=%d", static_cast<uint8_t>(it.register_type()),
|
||||
it.register_address(), it.register_count(), it.skip_updates);
|
||||
ESP_LOGCONFIG(TAG, " Range type=%u start=0x%X count=%d", static_cast<uint8_t>(it.register_type()),
|
||||
it.register_address(), it.register_count());
|
||||
}
|
||||
#endif
|
||||
}
|
||||
@@ -513,17 +497,19 @@ ModbusCommandItem ModbusCommandItem::create_custom_command(
|
||||
|
||||
bool ModbusCommandItem::send() {
|
||||
bool accepted;
|
||||
if (this->function_code_ != FunctionCode::CUSTOM) {
|
||||
if (this->custom_pdu_ != nullptr) {
|
||||
// Custom polling command: send the sensor's ready-made PDU (function code + data, no address byte)
|
||||
// to this controller's own device address; the hub prepends the address and appends the CRC.
|
||||
accepted = modbus::ModbusClientDevice::queue_pdu(std::span<const uint8_t>(*this->custom_pdu_));
|
||||
} else if (this->function_code_ != FunctionCode::CUSTOM) {
|
||||
accepted = this->queue_pdu(modbus::helpers::create_client_pdu(
|
||||
this->function_code_, this->start_address_, this->register_count_,
|
||||
this->payload.empty() ? nullptr : this->payload.data(), this->payload.size()));
|
||||
} else {
|
||||
// Custom command: the bytes are a complete raw frame (address + PDU). Send the PDU to the frame's own
|
||||
// address (which may differ from this controller's); the hub appends the CRC and routes the response
|
||||
// back to this item by pointer. (send_raw() is deprecated, so queue_pdu() is called with the extracted
|
||||
// address. Raw-frame semantics are kept here; the custom_pdu migration is a later step.)
|
||||
std::span<const uint8_t> frame =
|
||||
this->custom_data_ != nullptr ? std::span<const uint8_t>(*this->custom_data_) : this->payload;
|
||||
// Factory custom command: payload holds a complete raw frame (address + PDU). Send the PDU to the
|
||||
// frame's own address (which may differ from this controller's); the hub appends the CRC and routes
|
||||
// the response back to this item by pointer.
|
||||
std::span<const uint8_t> frame = this->payload;
|
||||
if (frame.empty()) {
|
||||
ESP_LOGW(TAG, "Empty custom command frame, not sent");
|
||||
accepted = false;
|
||||
|
||||
Reference in New Issue